Influence of Dialysis on the Glucose Profile in Patients with Diabetes: Usefulness of Continuous Glucose Monitoring

Abstract: We sought to investigate the impact of dialysis on glucose profiles of diabetic patients using continuous glucose monitoring (CGM). The study included 33 hemodialyzed patients with diabetes (14 females and 19 males; mean age: 66±8 years; patients with type 2 diabetes: 30; mean duration of dialysis: 3.8±2.6 years) who were under insulin treatment. After a run-in period, CGM was performed for 48 h, including a dialysis session. Three CGM sessions were proposed for each patient over a 3-month period. CGM results … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
24
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(26 citation statements)
references
References 8 publications
1
24
0
1
Order By: Relevance
“…Continuous glucose monitoring (CGM) is useful for elucidating BG variability in diabetes patients by analyzing the amplitude and timing of glucose fluctuations [22]. CGM is now commonly used for monitoring BG levels in patients undergoing maintenance hemodialysis [9,10,[23][24][25][26][27][28][29][30][31][32]. Nonetheless, there are only a few detailed reports on BG variability during hemodialysis therapy.…”
Section: Introductionmentioning
confidence: 99%
“…Continuous glucose monitoring (CGM) is useful for elucidating BG variability in diabetes patients by analyzing the amplitude and timing of glucose fluctuations [22]. CGM is now commonly used for monitoring BG levels in patients undergoing maintenance hemodialysis [9,10,[23][24][25][26][27][28][29][30][31][32]. Nonetheless, there are only a few detailed reports on BG variability during hemodialysis therapy.…”
Section: Introductionmentioning
confidence: 99%
“…In particular, hypoglycemia was more likely to occur during the 24 hours after a dialysis session, with a glucose nadir typically occurring during the 12 hours post‐dialysis in a majority of individuals 52 . During dialysis sessions and within the interdialytic period, fluid shifts between the interstitial fluid and intravascular space, uremia, acidosis, and volume overload all may impact the performance of the currently available CGM devices 52‐54 …”
Section: Assessment Of Glycemic Control In Eskdmentioning
confidence: 99%
“…The other two CGM devices of the last generation were used in a few studies: Navigator (Abbott, Rungis, France) in studies [36,37] and DexCom SEVEN PLUS (DexCom, CA, USA) in study [38]. Technologies, operations, and calibration procedures of these devices are similar to those described above.…”
Section: Glucose Determination With Continuous Glucose Monitoring (Cgmentioning