2017
DOI: 10.1055/s-0043-102941
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool

Abstract: ZUSAMMENFASSUNGZiel Ziel der Studie war den Einfluss einer intravenösen Kontrastmittelgabe auf phantomlos gemessene volumetrische Knochendichtewerte im Routine-MDCT zu evaluieren. Zusätz-lich sollte eine Formel zur Berechnung der wahrheitsgetreuen Knochendichte aus arteriell und venös gemessenen Werten aufgestellt werden. Material und Methodik 112 postmenopausale Frauen imAlter von 40 bis 77 Jahren (mittleres Alter 57,31; SD 9,61), die ein triphasisches MDCT (nativ, arteriell und venös) ABSTR AC TAim To eva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 22 publications
2
5
0
Order By: Relevance
“…The ndings of this study are in line with previous studies suggesting that the application of CM results in a systematic overestimation of CT-derived BMD [24][25][26]. Hence, CT attenuation values of osseous structures obtained from non-contrast and contrast-enhanced acquisitions cannot be readily compared and, most importantly, thresholds suggested for non-contrast acquisitions might not be applicable to contrast-enhanced acquisitions, and vice versa.…”
Section: Discussionsupporting
confidence: 76%
See 1 more Smart Citation
“…The ndings of this study are in line with previous studies suggesting that the application of CM results in a systematic overestimation of CT-derived BMD [24][25][26]. Hence, CT attenuation values of osseous structures obtained from non-contrast and contrast-enhanced acquisitions cannot be readily compared and, most importantly, thresholds suggested for non-contrast acquisitions might not be applicable to contrast-enhanced acquisitions, and vice versa.…”
Section: Discussionsupporting
confidence: 76%
“…Since the current state of research suggests that CT-derived BMD is substantially higher for acquisitions with iodinated contrast media (CM) application than for non-contrast acquisitions, the latter study was restricted to CT examinations without CM injection [24][25][26]. The aim of the present study was to examine the impact of CM application on CT-derived BMD in VCa and therefore to extend the applicability of calcium-only imaging for osteoporosis screening to contrast-enhanced CT acquisitions.…”
Section: Introductionmentioning
confidence: 99%
“…Yet, contrast media can drastically change attenuation within vertebral bone, which is due to its high vascularization 28 . Recently, it has been reported that the increase in vBMD values related to trabecular bone contrast perfusion could reach a plateau at approximately 7–9 %, which may be irrespective of the exact contrast phase and would make it comparatively easy to correct for 29 30 . However, universal correction for contrast-enhanced CT has not been achieved and is the subject of ongoing research, with many factors influencing attenuation values such as contrast phase and volume of injected contrast medium, heart ejection fraction, and extent of vascularization 18 19 .…”
Section: Overview Of Methods and Findingsmentioning
confidence: 99%
“…Iodine-containing contrast agents are frequently administered prior to a CT scan in order to increase the contrast of blood-containing vessels and tissues. These contrast agents increase CT values [ 34 , 43 , 44 , 74 , 75 ]. The impact on BMD depends on the amount of contrast agent, i.e., the concentration within the bone of interest at the time of the CT scan.…”
Section: Assessment Of Bmdmentioning
confidence: 99%
“…In some studies using datasets with and without contrast of the same subject, linear regression correction techniques were developed [ 34 , 45 , 76 , 77 ]; however, it is not entirely clear whether these techniques apply to the different scenarios in clinical routine and whether the linear correction factors obtained for one scanner can directly be used for different scanners and scan protocols [ 46 ]. Nevertheless, high correlations and good agreement between CT scans with and without contrast using linear corrections have been reported [ 74 , 76 , 77 ]. In the case of internal calibration, the change in the HU values of the internal reference materials after contrast administration remains to be studied [ 76 ].…”
Section: Assessment Of Bmdmentioning
confidence: 99%