2017
DOI: 10.1016/j.electacta.2017.05.006
|View full text |Cite
|
Sign up to set email alerts
|

Influence of boron content on the morphological, spectral, and electroanalytical characteristics of anodically oxidized boron-doped diamond electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
52
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 113 publications
(65 citation statements)
references
References 75 publications
4
52
0
1
Order By: Relevance
“…Macroscopic studies of the solvent window in several supporting electrolytes including chloride solutions, for differently doped nanocrystalline O‐BDD electrodes (anodically treated in acid) have been reported . It was also found that the solvent window decreased as the average boron doping level increased, and the cathodic onset potential was affected more by doping than the anodic one.…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…Macroscopic studies of the solvent window in several supporting electrolytes including chloride solutions, for differently doped nanocrystalline O‐BDD electrodes (anodically treated in acid) have been reported . It was also found that the solvent window decreased as the average boron doping level increased, and the cathodic onset potential was affected more by doping than the anodic one.…”
Section: Resultsmentioning
confidence: 94%
“…For macroscopic measurements of pBDD, it has been reported that the solvent window decreases slightly as the boron doping level increases, and that this effect is more marked on the cathodic side . However, others report no effect of boron doping and instead show the importance of sp 2 content, with the window narrowing with increasing sp 2 content of the electrode surface .…”
Section: Introductionmentioning
confidence: 99%
“…For some analytes, an APT‐BDDE was chosen as the sensor for the analytical application. However, a performance comparison with the analytical response of a CPT‐BDDE is not reported . In most cases, the use of the APT‐BDDE seems like a good option, being considered a successful strategy to prevent the fouling of the electrode.…”
Section: Electroanalytical Applications Of Electrochemically Pretreatmentioning
confidence: 99%
“…However, a performance comparison with the analytical response of a CPT-BDDE is not reported. [196][197][198][199][200][201][202][203] In most cases, the use of the APT-BDDE seems like a good option, being considered a successful strategy to prevent the fouling of the electrode. When melatonin was determined simply using an APT-BDDE, [201] no fouling effects were observed.…”
Section: Electroanalytical Applications Of Electrochemically Pretreatmentioning
confidence: 99%
See 1 more Smart Citation