2013
DOI: 10.1007/s10856-013-4935-0
|View full text |Cite
|
Sign up to set email alerts
|

Influence of acid-etching after grit-blasted on osseointegration of titanium dental implants: in vitro and in vivo studies

Abstract: Rough implant surfaces have shown improved osseointegration rates. In a majority of dental implants, the microrough surfaces are obtained by grit blasting and/or acid-etching. The aim of this contribution was to evaluate the effects of acid-etching, after the grit-blasted treatment in titanium dental implants, on surface wettability, surface energy, osteoblast responses and its osseointegration behavior. Four surfaces were studied: as-machined, acid-etched, micro-rough by grit-blasting and the combination grit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
57
0
3

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(63 citation statements)
references
References 24 publications
3
57
0
3
Order By: Relevance
“…Modification of implant surfaces can improve the biological behavior around implants and can accelerate the process of osseointegration. 28 The roughness and shape of the cavities …”
Section: Discussionmentioning
confidence: 99%
“…Modification of implant surfaces can improve the biological behavior around implants and can accelerate the process of osseointegration. 28 The roughness and shape of the cavities …”
Section: Discussionmentioning
confidence: 99%
“…Given the international medical trends, the present pieces of research contributed to the possibility of direct manufacturing of Ra roughness implants between 3-4 µm. This roughness is considered by doctors to represent the ideal surface that directly influences the mechanical fixation of the new bone tissue to the implant [11] . By reducing the roughness of the manufactured SLM pieces there will be a leading to the optimization of the post-processing methods, and the correlation of the process parameters (associated with the scanning of the outline) with the amount of the laser's adjustment beam, it reduces the dimensional deviation from ±0,1 mm to ±0,05 mm.…”
Section: Case Study -Customized Implants Fabricated By Slm Processmentioning
confidence: 99%
“…In vivo tests prove the fact that the treat surfaces can generate a better and faster osseointegration, in comparison with the even surfaces. From a clinical point of view, several studies have reported that on a long term the failure rate is lower in the case of the rough implants because they ensure the adhesion, the osteoblast cells proliferation and differentiation at the metal-bone interface [7,8,9,10,11] .…”
Section: Introductionmentioning
confidence: 99%
“…Tissue and cellular responses to the composition of the implant surface, specifically to the physical and chemical characteristics, have determined the clinical success of the procedures performed [2][3][4] . The osseointegration of titanium may be influenced by various mechanisms, especially the surface properties represented by the chemical characteristics such as structural composition; mechanical, such a residual stress; and, physical, such as wettability.…”
Section: Introductionmentioning
confidence: 99%