International Aegean Conference on Electrical Machines and Power Electronics and Electromotion, Joint Conference 2011
DOI: 10.1109/acemp.2011.6490700
|View full text |Cite
|
Sign up to set email alerts
|

Induction motors with changeable pole windings in the ratio 1:4

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…The leakage factor is defined with the following general formula [1], [2], [11], [13]- [15], [17], [30]- [32]:…”
Section: Differential Leakage Factor: a Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…The leakage factor is defined with the following general formula [1], [2], [11], [13]- [15], [17], [30]- [32]:…”
Section: Differential Leakage Factor: a Literature Reviewmentioning
confidence: 99%
“…With regards to asymmetrical windings, which present different winding factors for each phase, Heller et al [12] demonstrated the following expression of the differential leakage, which was also described and used by Cistelecan et al [22], [32]:…”
Section: Differential Leakage Factor: a Literature Reviewmentioning
confidence: 99%
“…In most cases these mechanisms operate under intense working conditions and with a high switching rate (up to 200 cycles/h). As investigations have shown [2,3], in electrical drives of this type a speed ratio of 1:4 is the most favourable, since with this ratio it is possible to reduce substantially electrical energy losses, and also the weight and size of the motors. Motors now in use usually have two separate windings on the stator for the two speeds.…”
Section: Introductionmentioning
confidence: 99%
“…Since pole-changing techniques can vary the operational frequency, many studies have been reported on their effectiveness [4][5][6][7]. To apply the pole-changing techniques for motors, the motor driven area can be expanded.…”
Section: Introductionmentioning
confidence: 99%
“…Since vehicles move using only the motor output in EVs, the above torque shock is directly transmitted to the driver. The other method uses multiple inverters with more controllable current phases than in the case of ordinary three‐phase inverters . To change the pole, the input current phase of each stator slot is optimized by current control.…”
Section: Introductionmentioning
confidence: 99%