2014
DOI: 10.17224/energagric.2015v30n2p155-163
|View full text |Cite
|
Sign up to set email alerts
|

Índice De Desconforto E Índice De Temperatura Efetiva: Uma Implementação Para Smartphones E Tablets.

Abstract: RESUMO:Índice de desconforto e índice de temperatura efetiva são métodos aplicados em análises de conforto térmico de ambientes. A computação móvel, por sua vez, relaciona-se com a capacidade de mover fisicamente serviços computacionais. Dentre as ferramentas disponíveis atualmente para avaliação das condições térmicas de ambientes mediante índices de conforto térmico, não há algoritmos específicos para plataforma de computação móvel. Sendo assim, este trabalho teve como objetivo desenvolver um aplicativo para… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Therefore, choosing controllers with the possibility of managing mechanisms to control the microenvironment has a good impact on optimizing the production cost and gain of productivity, so it was decided to use the Arduino Mega At2560, which was from the same working platform of the microcontrollers used by Neto et al (2015), Santos (2013), Oliveira (2016) and Oliveira et al (2015). The models used were: Uno, Mega 2560 and Genuino 101, being used always for the reception of sensor data.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, choosing controllers with the possibility of managing mechanisms to control the microenvironment has a good impact on optimizing the production cost and gain of productivity, so it was decided to use the Arduino Mega At2560, which was from the same working platform of the microcontrollers used by Neto et al (2015), Santos (2013), Oliveira (2016) and Oliveira et al (2015). The models used were: Uno, Mega 2560 and Genuino 101, being used always for the reception of sensor data.…”
Section: Resultsmentioning
confidence: 99%
“…HTU21d, humidity sensor used in this work, has a range of 0-100 % and accuracy of ± 2%, different from the sensor used by Oliveira et al (2015), who chose the humidity and temperature sensor DHT22, which has a resolution of ± 0.5 ºC (maximum: ± 1.0 ºC) with a range from 40 to 80 ºC (Oliveira, 2015). Santos (2013) used the relative humidity sensor STH21, which has typical accuracy of 0.04 °C, allowing readings in the range from 0 to 100% of relative humidity and temperature in the range from 20 to 100 °C (Santos, 2013).…”
Section: Resultsmentioning
confidence: 99%
“…Oliveira Júnior et al (2015) describe that the discomfort index can be applied in thermal comfort assessments, more common in human work environments, but can be applied in animal production facilities, in which the parameters must be adjusted according to the animal to be evaluated.…”
Section: Resultsmentioning
confidence: 99%
“…This instrument has been used in studies on dairy, beef cattle, swine, equine and poultry (Rojas-Downing et al, 2017;Tavares et al, 2016;Carneiro et al, 2015;Pérez et al, 2015;Silva et al, 2015;Nascimento et al, 2014;Neto & Nääs, 2014;Rosselle et al, 2014;Purswell & Davis, 2008) as well as in studies on humans (Saliba & Lanza, 2016;Oliveira Júnior et al, 2015;NR-15 (MTE, 1978).…”
Section: Introductionmentioning
confidence: 99%