Increasing the linear dynamic range in LC–MS: is it valid to use a less abundant isotopologue?

Abstract: Liquid chromatography-mass spectrometry (LC-MS) has quickly become the analytical method of choice in forensic toxicology laboratories due to its ability to detect a very wide range of compounds in a single analysis. One of the major limitations of LC-MS however, is a relatively limited linear dynamic range for quantitation. A new approach to combating this problem is to use the [ M + H] isotope mass peak for quantitation, thereby reducing saturation at the detector and extending the linear range. This is part… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 54 publications
0
4
0
Order By: Relevance
“…The difference in isotopic compositions of compounds from different sources theoretically can lead to different distributions of isotopologues and inaccurate quantitative results. However, a study by Trobbiani et al 17 evaluating the variation of Acceptance criteria for linearity: 75% of the calibration standards, including the LLOQ and ULOQ, have accuracy ranging from 85 to 115% (accuracy must be within 80-120% for LLOQ). This criteria is in line with the FDA guidance.…”
Section: Utilization Of Multiple Isotopologues -Additional Considerat...mentioning
confidence: 99%
“…The difference in isotopic compositions of compounds from different sources theoretically can lead to different distributions of isotopologues and inaccurate quantitative results. However, a study by Trobbiani et al 17 evaluating the variation of Acceptance criteria for linearity: 75% of the calibration standards, including the LLOQ and ULOQ, have accuracy ranging from 85 to 115% (accuracy must be within 80-120% for LLOQ). This criteria is in line with the FDA guidance.…”
Section: Utilization Of Multiple Isotopologues -Additional Considerat...mentioning
confidence: 99%
“…While the discussion and examples shown largely focus on advanced feature filtering, we also envision that the data provided by range and response calculations will be useful in the development of improved feature combination algorithms that go beyond the summation or averaging of features. Using detection limit information provided by the dilution series, it may become possible to extend the linear dynamic range in global profiling applications via a combination of isotopic measurements or fitting of intensity–calibration models between different ions. An improved understanding of the underlying patterns and physical chemistry mechanisms responsible for diversity in feature response functions may avoid the loss of information by allowing a more sophisticated amalgamation of data.…”
Section: Concluding Remarks and Future Directionsmentioning
confidence: 99%
“…As described by Trobbiani et al the approach of using a less abundant isotopologue may introduce a quantitative error when the reference standard for calibration is from a different source to the analyte in the samples as a result of different composition regarding isotopologues, which was our case [9]. Therefore, we compared the two reference standards and the relative abundance of the different isotopes is shown in Table 2.…”
Section: Mass Spectrometrymentioning
confidence: 99%