2018
DOI: 10.1177/0284185118774954
|View full text |Cite
|
Sign up to set email alerts
|

Increased diagnostic confidence in the diagnosis of pituitary micro-lesions with the addition of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions sequences

Abstract: Background Conventional magnetic resonance imaging (MRI) is adversely affected by thick slices, small intersection gaps, and the partial volume effect, leading to the missed diagnosis or misdiagnosis of pituitary micro-lesions. Purpose To evaluate the diagnostic yield of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-T2 SPACE) sequences compared with a standard MRI protocol for the diagnosis of pituitary micro-lesions. Material and Methods T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
7
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 14 publications
(13 reference statements)
0
7
0
1
Order By: Relevance
“…Регистрируется прогон с чередующимися импульсами возбуждения: +α и -α, где α -угол поворота. Затем регистрируется прогон с неизменным стабильным импульсом α вместо стандартных импульсов на 180° при рутинных последовательностях МРТ [6]. При этом формируются взаимно смещенные артефакты полос.…”
Section: Introductionunclassified
“…Регистрируется прогон с чередующимися импульсами возбуждения: +α и -α, где α -угол поворота. Затем регистрируется прогон с неизменным стабильным импульсом α вместо стандартных импульсов на 180° при рутинных последовательностях МРТ [6]. При этом формируются взаимно смещенные артефакты полос.…”
Section: Introductionunclassified
“…Moreover, threedimensional constructive interference in steady-state (3D-CISS) and three-dimensional sampling perfection with application-optimized contrasts by using different flip angle evolutions (3D-SPACE) sequences provide isotropic information and thinner images in any plane. 3D-SPACE is a T2-weighted 3D turbo spin-echo sequence using a variable flip angle instead of conventional 180° pulse sequences [6,7]. Thin sections result in better spatial resolution and reduced partial volume artifact.…”
Section: Introductionmentioning
confidence: 99%
“…Of course, due to the higher spatial resolution and higher image quality, 3 T scanners are slowly replacing the 1.5 T ones, but the latter are still used in medical imaging in many centers around the world [ 3 ]. The next step in pituitary imaging strategies was the application of various 3-D imaging techniques (e.g., T2 SPACE, GRASP, TWIST or IT-TWIST) to obtain increased sensitivity of multiplanar imaging, thinner layers, and even higher resolution while reducing artifacts [ 4 , 5 , 6 , 7 , 8 , 9 , 10 ]. Unfortunately, they have been mainly used thus far on adult patients and most of them require gadolinium administration.…”
Section: Introductionmentioning
confidence: 99%