2006 IEEE PES Power Systems Conference and Exposition 2006
DOI: 10.1109/psce.2006.296401
|View full text |Cite
|
Sign up to set email alerts
|

Incorporation of N-1 Security into Optimal Power Flow for FACTS Control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…The current injection method described in this paper is an extension of a basic method presented in [3]. To simulate the outage with the state before the outage as the initial situation, two types of current injections are introduced: I S , only non-zero at the ends of the faulted line, compensates the current on the actually faulted line [3] and I T is used to adapt the bus currents such that the power flow equations are fulfilled [6,11]. Fig.…”
Section: Current Injection Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The current injection method described in this paper is an extension of a basic method presented in [3]. To simulate the outage with the state before the outage as the initial situation, two types of current injections are introduced: I S , only non-zero at the ends of the faulted line, compensates the current on the actually faulted line [3] and I T is used to adapt the bus currents such that the power flow equations are fulfilled [6,11]. Fig.…”
Section: Current Injection Methodsmentioning
confidence: 99%
“…To minimise the deviations from the exact values, the injection currents obtained by solving (27) can be adapted by applying an additional correction step [11]. The equation system taking into account also the quadratic terms is defined by…”
Section: Current Injection Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The authors concluded that the proposed algorithm is very fast for mono-dimensional devices and is found to be time consuming for bi-dimensional FACTS devices. Glanzmann et al [56] (2006) developed a current injection method by which the power flow in any line during an outage can be calculated using linear equations. The current injection method was tossed by Bacher et al (1986) and Schnyder et al (1988), which has the advantage of not having to go through the cumbersome rebuilding of Power Flow iteration in case of any contingency and is implemented by the authors in this paper.…”
Section: Facts Incorporated Scopfmentioning
confidence: 99%
“…it is necessary to coordinate control actions among the regional operators by at the same time avoiding exposing local system data pertaining to regional infrastructure [5]. We consider loss minimization as the objective function and maintaining voltage profile within safe limits as the constraint.…”
mentioning
confidence: 99%