2022
DOI: 10.1016/j.est.2022.105744
|View full text |Cite
|
Sign up to set email alerts
|

Incorporation of controllable supercooled phase change material heat storage with a solar assisted heat pump: Testing of crystallization triggering and heating demand-based modelling study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…However, this short-term load shifting may not work very well if solar energy is the main heat source for the heat pump. Supercooled PCM can be effectively used for variable solar profiles as it can allow storage solar assisted heat pump's heat even for a week period at room temperature and still having some proportion of the latent heat [10]. Moreover, in order to increase the effectiveness of PCM usage in heat storage systems, controllable heat discharge can be key for more efficient systems because performance of using PCM in water tanks is dependent on the operating conditions [11].…”
Section: J O U R N a L P R E -P R O O Fmentioning
confidence: 99%
See 3 more Smart Citations
“…However, this short-term load shifting may not work very well if solar energy is the main heat source for the heat pump. Supercooled PCM can be effectively used for variable solar profiles as it can allow storage solar assisted heat pump's heat even for a week period at room temperature and still having some proportion of the latent heat [10]. Moreover, in order to increase the effectiveness of PCM usage in heat storage systems, controllable heat discharge can be key for more efficient systems because performance of using PCM in water tanks is dependent on the operating conditions [11].…”
Section: J O U R N a L P R E -P R O O Fmentioning
confidence: 99%
“…Englmair et al [21] investigated on-demand crystallisation of SAT in solar combi system, they calculated that annual solar fraction of 71% can be achieved by using 22.4 m 2 collector area and 1 m 3 PCM storage in a Danish passive house. Recently, Kutlu et al [10] carried out a simulation study of a solar-assisted heat pump unit with controllable SAT to provide space heating to a building. They presented that PCM J o u r n a l P r e -p r o o f storage tank can be charged in 6.5 hours and the stored tank can provide one-day heating, which will promote solar assisted heat pump instead of an air source heat pump.…”
Section: J O U R N a L P R E -P R O O Fmentioning
confidence: 99%
See 2 more Smart Citations