2008
DOI: 10.1007/s00340-008-3308-8
|View full text |Cite
|
Sign up to set email alerts
|

Incoherent broadband cavity enhanced absorption spectroscopy for in situ measurements of NO2 with a blue light emitting diode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
37
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(40 citation statements)
references
References 37 publications
0
37
1
Order By: Relevance
“…99.8% at 365 nm and a 5 m radius of curvature. Focusing the beam into the cavity centre improved the cavity quality and minimised dispersion losses (Fiedler et al, 2007;Wu et al, 2008). Light exiting the cavity was focussed into a Czerny-Turner spectrograph (Andor SR-163) with a 163 cm focal length and a 1200 l mm −1 , 300 nm blaze grating.…”
Section: Spectrometer Setupmentioning
confidence: 99%
“…99.8% at 365 nm and a 5 m radius of curvature. Focusing the beam into the cavity centre improved the cavity quality and minimised dispersion losses (Fiedler et al, 2007;Wu et al, 2008). Light exiting the cavity was focussed into a Czerny-Turner spectrograph (Andor SR-163) with a 163 cm focal length and a 1200 l mm −1 , 300 nm blaze grating.…”
Section: Spectrometer Setupmentioning
confidence: 99%
“…[5]). Since its advent, CEAS has found numerous applications in detecting trace species [5][6][7][8][9][10][11][12][13][14][15], studies of gas phase kinetics [16][17][18][19][20][21], capturing weak molecular transitions [22][23][24][25][26] and probing interfacial interactions [27][28][29] and molecular dynamics [30].…”
mentioning
confidence: 99%
“…This allows for real time and simultaneous measurement of NO 2 and NO 3 concentrations with detection limits of respectively 600 pptv and 2 pptv, for an optimal 400 s acquisition time. Relatively compact IBB-CEAS setups based on a LED have been previously reported [16,18,19,21]. The lower detection limit reported for NO 3 is 2.5 pptv measured around 662 nm for a 516 s acquisition time [16].…”
Section: Introductionmentioning
confidence: 99%
“…Different analyzers based on Light Induced Fluorescence (LIF) [11], Cavity Ring Down Spectroscopy (CRDS) [12], Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) [13], cavity-attenuated phase shift spectroscopy [14], Incoherent Broad-Band Cavity-Enhanced Absorption Spectroscopy (IBB-CEAS) [15][16][17][18][19][20][21] have been developed. The instrument described here is in the continuity of our previous work [20], based on the IBB-CEAS technique.…”
Section: Introductionmentioning
confidence: 99%