2008
DOI: 10.1016/s0076-6879(08)01220-2
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Real‐Time Measurement of Nitric Oxide in Anesthetized Rat Brain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
38
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 66 publications
(40 citation statements)
references
References 38 publications
2
38
0
Order By: Relevance
“…38 ROS generation in VSMCs cocultured with L-NAME-treated ECs was similar to that in VSMCs cocultured with vehicle-treated ECs, indicating that negative modulatory effects of ECs are probably eNOS-independent. However, because NO has a very short half-life and diffuses only short distances from its site of production, 38,39 we cannot exclude the possibility that NO may be converted to nitrate and nitrite before it takes effect in VSMCs. We also explored the possibility that Cox2-derived PGI 2 and 20-HETE, other important EC-derived mediators, 40,41 may influence redox homeostasis in VSMCs.…”
Section: Discussionmentioning
confidence: 99%
“…38 ROS generation in VSMCs cocultured with L-NAME-treated ECs was similar to that in VSMCs cocultured with vehicle-treated ECs, indicating that negative modulatory effects of ECs are probably eNOS-independent. However, because NO has a very short half-life and diffuses only short distances from its site of production, 38,39 we cannot exclude the possibility that NO may be converted to nitrate and nitrite before it takes effect in VSMCs. We also explored the possibility that Cox2-derived PGI 2 and 20-HETE, other important EC-derived mediators, 40,41 may influence redox homeostasis in VSMCs.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore it is plausible that this translates to the results described within, whereby salts from the PBS electrolyte adsorb on the Nafion ® surface after repeated exposure, compromising its integrity over time. Previously, a number of groups have investigated the simultaneous combination of Nafion ® and PPD on carbon fiber electrodes in the expectation of improving sensor performance [6,16,17,39]. Two variations of this polymer combination were investigated and the results are presented in Table 1.…”
Section: Shelf-life Studies-effect Of Repeated Aa Calibrationsmentioning
confidence: 99%
“…In vivo, NO is available in low concentration and it has a short half-life and high reactivity with other biological molecules. 52 Therefore, it is very challenging to perform the NO real-time measurement in vivo. Tsai and colleague used microelectrodes coated with Nafion to measure perivascular NO at the end of microhemodynamic measurement by removing a coverglass of dorsal skinfold chamber.…”
Section: Gas Transport Measurementmentioning
confidence: 99%