2012
DOI: 10.1080/02786826.2011.652749
|View full text |Cite
|
Sign up to set email alerts
|

In-Vivo Measurements of Micrometer-Sized Particle Deposition in the Nasal Cavities of Taiwanese Adults

Abstract: It has been observed that Asians and Caucasians possess considerably different craniofacial features, which may affect the anatomical structure of the upper respiratory tract and, consequently, the characteristics of particle deposition. Most deposition studies on the human respiratory tract were primarily based on a limited number of Caucasian subjects. Therefore, data of the particle deposition efficiency in the upper respiratory tract of Asians are needed to supplement the understanding of the deposition ch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
25
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(28 citation statements)
references
References 38 publications
(41 reference statements)
3
25
0
Order By: Relevance
“…For consistency with the reported experimental and numerical data, particles were released uniformly from the nostrils using the 'nasal-only' model. For inertial parameter less than 10 4 , the numerical result shows good agreement with Kelly et al [50] (SLA,VIPER) and Schroeter et al [51] (Model A, B, C), and lower than Hsu et al [52]. While for inertial parameter larger than 10 4 , the numerical result matches Hsu et al [52] result more.…”
Section: Verification For Particle Simulationsupporting
confidence: 87%
See 1 more Smart Citation
“…For consistency with the reported experimental and numerical data, particles were released uniformly from the nostrils using the 'nasal-only' model. For inertial parameter less than 10 4 , the numerical result shows good agreement with Kelly et al [50] (SLA,VIPER) and Schroeter et al [51] (Model A, B, C), and lower than Hsu et al [52]. While for inertial parameter larger than 10 4 , the numerical result matches Hsu et al [52] result more.…”
Section: Verification For Particle Simulationsupporting
confidence: 87%
“…For inertial parameter less than 10 4 , the numerical result shows good agreement with Kelly et al [50] (SLA,VIPER) and Schroeter et al [51] (Model A, B, C), and lower than Hsu et al [52]. While for inertial parameter larger than 10 4 , the numerical result matches Hsu et al [52] result more. When comparing with [51] three models of different surface roughness, the deposition efficiency of NC0 3 is higher than that of the smoothest model C, but lower than that of the roughest model A, and fits that of the model B the best.…”
Section: Verification For Particle Simulationsupporting
confidence: 87%
“…Particle deposition in the nasal cavity was compared to experimental data reported by [61, 62] and numerical data [47, 49, 63] (see Fig 8) where the flow rate used for the comparison was a constant 20L/min. In order to standardize the results, the inertial parameter (IP) was used, i.e.…”
Section: Methodsmentioning
confidence: 99%
“…Deposition in adult nasal airways has been well investigated through in vivo and in vitro measurements and in silico simulations, e.g., Hsu and Chuang (2012) and Walenga et al (2014) and references therein. Far fewer studies have been carried out to quantify nasal deposition in children and have compared filtration in children to adults (Becquemin et al 1991;Bennett et al 2008;Golshahi et al 2011;Phalen et al 1989) but with varying results.…”
Section: Introductionmentioning
confidence: 99%