2011
DOI: 10.1016/j.ajodo.2010.05.022
|View full text |Cite
|
Sign up to set email alerts
|

In-vivo evaluation of salivary nickel and chromium levels in conventional and self-ligating brackets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
35
0
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 29 publications
(39 citation statements)
references
References 25 publications
3
35
0
1
Order By: Relevance
“…In group 1, only ten subjects were treated with conventional (MBT preadjusted edgewise brackets) fixed appliance system and additional ten patients received self-ligating (SmartClip TM ) fixed appliance system (group 2). Both groups had 16 brackets, four bands as well as 0.016 inch NiTi wires (3M Unitec) and unstimulated saliva samples were collected 1 hour before, 1, 7 and 30 days after placement of appliances [40]. In contrast to our investigation, the authors used an atomic absorption spectrometer to determine Ni +2 levels in patients` saliva [40].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In group 1, only ten subjects were treated with conventional (MBT preadjusted edgewise brackets) fixed appliance system and additional ten patients received self-ligating (SmartClip TM ) fixed appliance system (group 2). Both groups had 16 brackets, four bands as well as 0.016 inch NiTi wires (3M Unitec) and unstimulated saliva samples were collected 1 hour before, 1, 7 and 30 days after placement of appliances [40]. In contrast to our investigation, the authors used an atomic absorption spectrometer to determine Ni +2 levels in patients` saliva [40].…”
Section: Discussionmentioning
confidence: 99%
“…Both groups had 16 brackets, four bands as well as 0.016 inch NiTi wires (3M Unitec) and unstimulated saliva samples were collected 1 hour before, 1, 7 and 30 days after placement of appliances [40]. In contrast to our investigation, the authors used an atomic absorption spectrometer to determine Ni +2 levels in patients` saliva [40]. Atomic absorption spectrometer has a higher detection threshold and inferior resolution than inductively-coupled plasma mass spectrometry [5,27,37,38,44].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Así, con la administración de acetato tetrahidrato de Ni, hexahidrato de cloruro de Ni, sulfamato tetrahidratado de Ni y hexahidrato sulfato de Ni, con una dosis dese puede concluir que existe un leve aumento de liberación de níquel en los primeros días de tratamiento que se va reduciendo progresivamente con el tiempo (i.e. contenido de níquel en saliva de sujetos con ortodoncia de 18.5 ± 13.1 ng/mL frente a valores de 11.9 ± 11.4 ng/mL en sujetos control) (Amini, Jafari, Amini, & Sepasi, 2012;Karnam, Naveen, & Manjith, 2012;Mikulewicz & Chojnacka, 2010;Sahoo, Kailasam, Padmanabhan, & Chitharanjan, 2011). A pesar de ello, no se ha descrito que lleguen a alcanzarse niveles tóxicos; aún así es recomendable efectuar este tipo de estudios sobre todo, en pacientes con alergias en las que podría estar implicado el Ni (Navarro & Gil, 2010).…”
Section: Estudios De Biodisponibilidad In Vivounclassified