In vivo dosimetry in low-voltage IORT breast treatments with XR-RV3 radiochromic film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 50 publications
0
9
0
Order By: Relevance
“…Gafchromic films in kV energy beams often give rise to the question of energy dependence, both with respect to the megavoltage beams (e.g., 6 MV–15 MV photon beam) and the beam hardening effect. 15 , 19 , 20 , 30 , 31 Monte Carlo simulations by Moradi et al had shown that the 50 kV beam hardens with the use of spherical applicators and distance from the tip of the XRS source. 32 …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Gafchromic films in kV energy beams often give rise to the question of energy dependence, both with respect to the megavoltage beams (e.g., 6 MV–15 MV photon beam) and the beam hardening effect. 15 , 19 , 20 , 30 , 31 Monte Carlo simulations by Moradi et al had shown that the 50 kV beam hardens with the use of spherical applicators and distance from the tip of the XRS source. 32 …”
Section: Discussionmentioning
confidence: 99%
“…Gafchromic films in kV energy beams often give rise to the question of energy dependence, both with respect to the megavoltage beams (e.g., 6 MV-15 MV photon beam) and the beam hardening effect. 15,19,20,30,31 Monte Carlo simulations by Moradi et al had shown that the 50 kV beam hardens with the use of spherical applicators and distance from the tip of the XRS source. 32 The energy dependence of Gafchromic films also varied with different types, generally categorized by the radiology films (XR-series) and the radiotherapy films (EBT-series).…”
Section: Ebt3 Film Dosimetrymentioning
confidence: 99%
See 2 more Smart Citations
“…However, they under-respond to photon energies lower than 100 keV 8 , and exhibit LET dependence for protons. 10 In kV X-rays applications, such as dose measurements in interventional radiology or IORT 11 , XR-RV3 films should be used instead. In the energy range of these applications, films are strongly energy dependent and should be calibrated for each energy in use.…”
Section: Radiochr Omic Filmsmentioning
confidence: 99%