2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) 2003
DOI: 10.1109/nssmic.2003.1352182
|View full text |Cite
|
Sign up to set email alerts
|

In vivo dosimetry and seed localization in prostate brachytherapy with permanent implants

Abstract: Abstract-This paper reports on the development of an interactive, intraoperative dose planning system for seed implant brachytherapy in cancer treatment. This system involves in vivo dosimetry and the ability to determine implanted seed positions. The first stage of this project is the development of a urethral alarm probe to measure the dose along the urethra during a prostate brachytherapy treatment procedure. Ultimately, the system will be used to advise the physicians upon reaching a preset dose rate or do… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…Previous investigations of the concept of spectroscopic dosimetry by Cutajar et al [10,11] determined spectroscopic dosimetry to be accurate to within ±2.5 % over the same 50 mm range. The urethral minidosimeter simulations were deemed suitable to be used to model the effects of modifying the urethral mini-dosimeter construction on the dosimetry.…”
Section: Methodsmentioning
confidence: 92%
See 1 more Smart Citation
“…Previous investigations of the concept of spectroscopic dosimetry by Cutajar et al [10,11] determined spectroscopic dosimetry to be accurate to within ±2.5 % over the same 50 mm range. The urethral minidosimeter simulations were deemed suitable to be used to model the effects of modifying the urethral mini-dosimeter construction on the dosimetry.…”
Section: Methodsmentioning
confidence: 92%
“…The Centre for Medical Radiation Physics (CMRP) at the University of Wollongong (UOW) in Australia has developed an intra-operative dosimetry system based on in vivo photon spectroscopy [10,11] to accurately measure the dose rate along the urethra LDR prostate brachytherapy. The system is based on a silicon mini detector directly coupled to a novel miniature amplifier system of sub millimetre size within a thin urethral probe.…”
Section: Introductionmentioning
confidence: 99%
“…Occasional IVD feasibility studies have also been conducted in some clinics. [12][13][14][15][16][17][18][19][20][21][22][23][24] However, routine implementations of IVD for error detection monitoring and QA of the BT treatments is yet to come. One reason for this may be that the cost vs benefit relation of IVD is not established and that robust IVD systems that do not leave a significant footprint on the treatment workflow are not commercially available.…”
Section: Treatment Errors In Btmentioning
confidence: 99%
“…We have developed a probe which measures in real time the dose delivered along the urethra and may be used by the physicians during seed implantation to monitor for excessive doses. In vivo dosimetry is commonly performed with miniature radiation detectors such as MOSFETs or diodes 1) . The main disadvantages of such systems are energy dependence and low sensitivity.…”
Section: Introductionmentioning
confidence: 99%