2011
DOI: 10.1016/j.jbiotec.2011.06.043
|View full text |Cite
|
Sign up to set email alerts
|

In vitro selection and characterization of DNA aptamers recognizing chloramphenicol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
75
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 135 publications
(75 citation statements)
references
References 33 publications
0
75
0
Order By: Relevance
“…25% ammonia (NH 3 $H 2 O), 25% glutaraldehyde (OHC(CH 2 ) 3 CHO), tetraethyl orthosilicate (TEOS), 1,6-hexanediamine, anhydrous sodium acetate, acetone, FeCl 3 $6H 2 O, NaF, NaOH, glycol, cyclohexane, ethanol were of analytical grade and were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). CAP aptamer (reported by Mehta et al (2011)) and its part complementary strand were synthesized by Shanghai Sangon Biological Science & Technology Company (Shanghai, China). The sequence of the CAP aptamer is 5 0 -biotin-AGCAGCA-CAGAGGTCAGATGACTTCAGTGAG TTGTCCCACGGTCGGC-GAGTCGGTGGTAGCCTATGCGTGCTACCGTGAA-3 0 , the sequence of its part complementary DNA is 5 0 eNH 2 eCGACCGTGGGACAACTC A-3 0 .…”
Section: Reagents and Apparatusmentioning
confidence: 99%
“…25% ammonia (NH 3 $H 2 O), 25% glutaraldehyde (OHC(CH 2 ) 3 CHO), tetraethyl orthosilicate (TEOS), 1,6-hexanediamine, anhydrous sodium acetate, acetone, FeCl 3 $6H 2 O, NaF, NaOH, glycol, cyclohexane, ethanol were of analytical grade and were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). CAP aptamer (reported by Mehta et al (2011)) and its part complementary strand were synthesized by Shanghai Sangon Biological Science & Technology Company (Shanghai, China). The sequence of the CAP aptamer is 5 0 -biotin-AGCAGCA-CAGAGGTCAGATGACTTCAGTGAG TTGTCCCACGGTCGGC-GAGTCGGTGGTAGCCTATGCGTGCTACCGTGAA-3 0 , the sequence of its part complementary DNA is 5 0 eNH 2 eCGACCGTGGGACAACTC A-3 0 .…”
Section: Reagents and Apparatusmentioning
confidence: 99%
“…Aptamers are superior to antibodies because of their broader range of application. They are able to bind not only to proteins (Tang et al 2007;Hasegawa et al 2008;Tsukakoshi et al 2010) but also to other molecules, including metal ions (Kawakami et al 2000), and small molecules (Mann et al 2005;Niazi et al 2008;Cruz-Aguado and Penner 2008;Kim et al 2010;Mehta et al 2011).…”
Section: Introductionmentioning
confidence: 99%
“…3, once the CAP and PCB72 were added to the biosensor, a competitive-type displacement reaction was happened between the targets (CAP and PCB72) and the tracers, resulting in peak current increased due to the release of tracers. The binding constant of CAP-aptamer and PCB72-aptamer coated magnetic beads are 1.31 Â 10 6 M À 1 and 1.67 Â 10 7 M À 1 , respectively (Mehta et al, 2011. With the increased concentration of CAP and PCB72, the current of lead and cadmium increased in the meantime, respectively.…”
Section: Analytical Performancementioning
confidence: 97%