2013
DOI: 10.1016/j.ijom.2012.07.008
|View full text |Cite
|
Sign up to set email alerts
|

In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
31
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(35 citation statements)
references
References 29 publications
2
31
0
2
Order By: Relevance
“…The sheep mandible has been chosen for these studies because of its similarities in size and thickness to the human mandible (Wittenberg et al). A few studies that used the entire mandible included mechanical tests with the possibility of applying homolateral and contralateral levers (Pereira-Filho et al, 2013;Trivellato et al, 2014). Finally, we must consider that a metallic support on bearings was used for the mechanical test, allowing the movement and deformation of the mandibles as a whole during the application of the load, to imitate the freedom of functional movement of a human mandible, docked in the mandibular cavities and free in all other regions (Landgraf).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The sheep mandible has been chosen for these studies because of its similarities in size and thickness to the human mandible (Wittenberg et al). A few studies that used the entire mandible included mechanical tests with the possibility of applying homolateral and contralateral levers (Pereira-Filho et al, 2013;Trivellato et al, 2014). Finally, we must consider that a metallic support on bearings was used for the mechanical test, allowing the movement and deformation of the mandibles as a whole during the application of the load, to imitate the freedom of functional movement of a human mandible, docked in the mandibular cavities and free in all other regions (Landgraf).…”
Section: Resultsmentioning
confidence: 99%
“…Polyurethane hemimandibles have been used in many studies regarding fixation systems for fractures or orthognathic surgery (Goulart et al; de Medeiros et al;Pereira-Filho et al, 2013Peterson et al;Lima et al). However, the natural mandible has a single response under stress that should be taken into account in the choice of substrate to be used in the studies, and this presents the possibility of entrapment observed after fracture.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite their greater flexibility due to their larger grains, the G4 plates have optimal mechanical strength. Iamashita et al [25], evaluating three fixation techniques used for sagittal osteotomy of the mandibular branch, using the same G4 commercial brand system, reported a lower resistance of the plates to compressive loads when compared to that of the bicortical screws; what was expected due to different fixation techniques used.…”
Section: Discussionmentioning
confidence: 98%
“…The international literature has shown that the use of three bicortical screws in an inverted‐L pattern produces better mechanical resistance than miniplates. However, the use of this method carries the risk of damage to adjacent structures, such as teeth, nerves or vessels, due to a need for transcutaneous access.…”
Section: Introductionmentioning
confidence: 99%