In Vitro and In Vivo Toxicometabolomics of the Synthetic Cathinone PCYP Studied by Means of LC-HRMS/MS

Abstract: Synthetic cathinones are one important group amongst new psychoactive substances (NPS) and limited information is available regarding their toxicokinetics and -dynamics. Over the past few years, nontargeted toxicometabolomics has been increasingly used to study compound-related effects of NPS to identify important exogenous and endogenous biomarkers. In this study, the effects of the synthetic cathinone PCYP (2-cyclohexyl-1-phenyl-2-(1-pyrrolidinyl)-ethanone) on in vitro and in vivo metabolomes were investigat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 57 publications
0
6
0
Order By: Relevance
“…Since the aim of this study was to evaluate the influence of different analytical LC columns on the resolution of selected endogenous compounds and the results of untargeted metabolomics analyses, only columns were changed and other parameters remained unchanged. However, eluents and gradients had to be adopted and were selected according to the column types and as used in other studies (Hemmer et al, 2022 ; Manier et al, 2019b ; Merck, 2019 , 2020 ; Michely & Maurer, 2018 ). In addition, the choice of mobile phases was evaluated by the detectability of different compound classes using a system suitability test mixture described in the Experimental Section of the Supplementary Information .…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Since the aim of this study was to evaluate the influence of different analytical LC columns on the resolution of selected endogenous compounds and the results of untargeted metabolomics analyses, only columns were changed and other parameters remained unchanged. However, eluents and gradients had to be adopted and were selected according to the column types and as used in other studies (Hemmer et al, 2022 ; Manier et al, 2019b ; Merck, 2019 , 2020 ; Michely & Maurer, 2018 ). In addition, the choice of mobile phases was evaluated by the detectability of different compound classes using a system suitability test mixture described in the Experimental Section of the Supplementary Information .…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the choice of mobile phases was evaluated by the detectability of different compound classes using a system suitability test mixture described in the Experimental Section of the Supplementary Information . Sample preparations and all other LC-HRMS parameters such as column oven temperature, and MS settings were identical for all columns according to previously published studies (Hemmer et al, 2022 ; Manier et al, 2019b ).
Fig.
…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations