2015
DOI: 10.1016/j.desal.2015.02.005
|View full text |Cite
|
Sign up to set email alerts
|

In situ investigation of combined organic and colloidal fouling for nanofiltration membrane using ultrasonic time domain reflectometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 37 publications
0
11
0
Order By: Relevance
“…The UTDR results of NF experiments showed that the fouling layer obtained from the combined organic-colloidal fouling (mixed silica and bovine serum albumin (BSA) and silica and NaCl solution) was denser than that obtained from the colloidal fouling layer in the presence of NaCl. The formation of the denser fouling layer was due to the electrostatic interactions between foulants and membrane surface as well as the electrostatic interactions among the foulants due to absorption of BSA onto silica [116]. Taheri, et al [119] used UTDR technique to provide a good estimation of the fouling layer thickness formed during RO tests.…”
Section: Ultrasonic Time Domain Reflectometry (Utdr)mentioning
confidence: 99%
See 3 more Smart Citations
“…The UTDR results of NF experiments showed that the fouling layer obtained from the combined organic-colloidal fouling (mixed silica and bovine serum albumin (BSA) and silica and NaCl solution) was denser than that obtained from the colloidal fouling layer in the presence of NaCl. The formation of the denser fouling layer was due to the electrostatic interactions between foulants and membrane surface as well as the electrostatic interactions among the foulants due to absorption of BSA onto silica [116]. Taheri, et al [119] used UTDR technique to provide a good estimation of the fouling layer thickness formed during RO tests.…”
Section: Ultrasonic Time Domain Reflectometry (Utdr)mentioning
confidence: 99%
“…UTDR was used for fouling detection by different authors in filtration processes. As an example, Li, et al [116] investigated the fouling behavior of mixed silica-BSA solution and silica-NaCl solution using UTDR technique in NF membranes (see Figure 6). The UTDR results of NF experiments showed that the fouling layer obtained from the combined organic-colloidal fouling (mixed silica and bovine serum albumin (BSA) and silica and NaCl solution) was denser than that obtained from the colloidal fouling layer in the presence of NaCl.…”
Section: Ultrasonic Time Domain Reflectometry (Utdr)mentioning
confidence: 99%
See 2 more Smart Citations
“…Ultrasonic signal responses of the clean NF membrane (blue line) and differential signals (red line) obtained at 300 min of fouling operation with the feed solution of 1000 mg/L silica and 1000 mg/L NaCl under a constant pressure operation. Adapted with permission from[116], Copyright Elsevier, 2015.…”
mentioning
confidence: 99%