2000
DOI: 10.1002/(sici)1522-2683(20000401)21:7<1395::aid-elps1395>3.0.co;2-c
|View full text |Cite
|
Sign up to set email alerts
|

In-line coupling capillary electrochromatography with amperometric detection for analysis of explosive compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2000
2000
2007
2007

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 53 publications
(12 citation statements)
references
References 24 publications
0
9
0
1
Order By: Relevance
“…Compared with HPLC, pCEC-AD possesses the predominance of very low sample and organic solvent consumption, better resolution, potentially higher peak capacities, and shorter analysis time. In 2000, Hilmi and Luong [17] reported a home-made pure CEC with electrochemical detection system, which was typically operated in the amperometric mode. Subsequently a simple homemade system based on the end-column amperometric detector coupled with unique pCEC was developed and applied for the separation and determination of three estrogens in our group [18].…”
Section: Introductionmentioning
confidence: 99%
“…Compared with HPLC, pCEC-AD possesses the predominance of very low sample and organic solvent consumption, better resolution, potentially higher peak capacities, and shorter analysis time. In 2000, Hilmi and Luong [17] reported a home-made pure CEC with electrochemical detection system, which was typically operated in the amperometric mode. Subsequently a simple homemade system based on the end-column amperometric detector coupled with unique pCEC was developed and applied for the separation and determination of three estrogens in our group [18].…”
Section: Introductionmentioning
confidence: 99%
“…Uma ampla variedade de materiais (e dimensões) tem sido empregada na fabricação dos microeletrodos. Há na literatura a descrição de eletrodos confeccionados com fibra 40 66,144,145,147,148,182,188,[190][191][192]194,195 . Eletrodos modificados oferecem diferentes possibilidades de detecção, como, por exemplo, a diminuição dos potenciais de oxidação ou redução de diversas espécies.…”
Section: Detecção Amperométrica (Ad)unclassified
“…Both groups utilized methanol, SDS and 2-(N-morpholino)ethanesulfonic acid in their buffers. UV [48] and amperometric [49] detection were performed.…”
Section: Explosives Residue Gunshot Residue Ink and Dye Analysismentioning
confidence: 99%