Impulse and Alternating Current Tests on Grounding Electrodes in Soil Environment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
1

Year Published

1993
1993
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(9 citation statements)
references
References 1 publication
0
7
0
1
Order By: Relevance
“…A review of field testing and measurement of impulse tests on grounding systems was firstly performed, to present various test set-ups and arrangements adopted in previously published works [2,8,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22]…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…A review of field testing and measurement of impulse tests on grounding systems was firstly performed, to present various test set-ups and arrangements adopted in previously published works [2,8,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22]…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
“…The study of soil behavior under impulse condition by means of field testing showed that the resistance decreased with increasing current [2,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. It was noted from these studies [2,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] that the main concerns in the field measurements are the costs, logistics and time challenges. The guidelines were also found to be limited, due to the limited standards for field testing and measurements of grounding systems under high impulse conditions.…”
Section: Review Of Field Testing and Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…For wide soil, the configuration is designed using horizontal or grid configuration. The horizontal or grid grounding impedance has a more stable value than the vertical configuration because the area of grounding space is very large [4].…”
Section: Introductionmentioning
confidence: 99%
“…The application of such electrodes for power frequency requirements is well understood. However, the high frequency and transient characteristics of earthing systems requires better understanding, as evidenced by published research [1][2][3][4][5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%