2021
DOI: 10.1016/j.jobe.2020.101990
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of standards on fire safety performance of externally insulated high-rise buildings: Focusing on the case in Korea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 37 publications
2
3
0
Order By: Relevance
“…The results agree with previous findings that Fire Safety Awareness is a standard measure used in the fire safety management of workers in a hospitality environment (Agbola & Falola, 2021;Hassanain, Aljuhani, Hamida, & Salaheldin, 2022;Kim et al, 2021;Li, Hasemi, Nozoe, & Nagasawa, 2021;Ogochukwu et al, 2019). The results also showed that over 80% of respondents agreed to be conversant with the fire safety awareness in the hotel building.…”
Section: Worker's Awareness Of Fire Safetysupporting
confidence: 92%
See 2 more Smart Citations
“…The results agree with previous findings that Fire Safety Awareness is a standard measure used in the fire safety management of workers in a hospitality environment (Agbola & Falola, 2021;Hassanain, Aljuhani, Hamida, & Salaheldin, 2022;Kim et al, 2021;Li, Hasemi, Nozoe, & Nagasawa, 2021;Ogochukwu et al, 2019). The results also showed that over 80% of respondents agreed to be conversant with the fire safety awareness in the hotel building.…”
Section: Worker's Awareness Of Fire Safetysupporting
confidence: 92%
“…The results agree with the findings by Kim et al (2021), for overall improvements in Fire Safety, especially in high-rise buildings, in line with the British Standard (-8) 9999 policy (Alianto, Nasruddin, & Nugroho, 2022;Brzezinska & Bryant, 2021;Hopkin & Spearpoint, 2021). As hypothesized, each of these dimensions was found to be a significant factor in safety policy, as in management commitment to fire safety, supervisor support, safety communication, safety policies, and safety programs.…”
Section: Management's Commitment To Policysupporting
confidence: 89%
See 1 more Smart Citation
“…Moreover, the fire is highly likely to develop into a large-scale fire when it starts in a closed space. Australia, China, and the UK have recently increased their level of awareness of the fire risks in major buildings in relation to highly flammable exterior cladding panels [35][36][37].…”
Section: Results Of Fire Safety Expert Surveymentioning
confidence: 99%
“…Apart from the insulation materials themselves, similar concerns arise for insulation systems as proprietary products when those are installed in high rise buildings. Their use necessitates rigorous fire testing to clearly document and understand their behaviour [50]. Similar full scale, destructive fire testing is 1196 (2023) 012112 IOP Publishing doi:10.1088/1755-1315/1196/1/012112 9 becoming a more common occurrence and necessity in timber structures since this type of construction is more favourable towards sustainable design and lower environmental footprint of new developments [51][52].…”
Section: Fire Engineering and Sustainabilitymentioning
confidence: 99%