2010
DOI: 10.1120/jacmp.v11i4.3331
|View full text |Cite
|
Sign up to set email alerts
|

Improved volumetric imaging in tomosynthesis using combined multiaxial sweeps

Abstract: This study explores the volumetric reconstruction fidelity attainable using tomosynthesis with a kV imaging system which has a unique ability to rotate isocentrically and with multiple degrees of mechanical freedom. More specifically, we seek to investigate volumetric reconstructions by combining multiple limited‐angle rotational image acquisition sweeps. By comparing these reconstructed images with those of a CBCT reconstruction, we can gauge the volumetric fidelity of the reconstructions. In surgical situati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 17 publications
0
1
0
Order By: Relevance
“…10 Various configurations of DTS scans have been explored and their effects on the quality of reconstructed DTS images have been investigated. 11,13 In this paper, we describe and demonstrate dual-view DTS technique with both simulation and experimental studies. With the dual-view DTS technique, projection images are acquired in two orthogonal views, PA and lateral, and then reconstructed with an iterative algorithm to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view.…”
Section: Introductionmentioning
confidence: 99%
“…10 Various configurations of DTS scans have been explored and their effects on the quality of reconstructed DTS images have been investigated. 11,13 In this paper, we describe and demonstrate dual-view DTS technique with both simulation and experimental studies. With the dual-view DTS technique, projection images are acquired in two orthogonal views, PA and lateral, and then reconstructed with an iterative algorithm to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view.…”
Section: Introductionmentioning
confidence: 99%