1993
DOI: 10.1006/jmra.1993.1019
|View full text |Cite
|
Sign up to set email alerts
|

Improved Proton-Detected Heteronuclear Correlation Using Gradient-Enhanced z and zz Filters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
64
0

Year Published

1994
1994
2013
2013

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(67 citation statements)
references
References 0 publications
3
64
0
Order By: Relevance
“…2A, was recorded over 16 h using a 5 mM solution of a-hCG. The high quality of this spectrum was achieved by the combination of spoiler gradients and phase cycling to suppress pulse artifacts [16,26,32]. In Fig.…”
Section: Resultsmentioning
confidence: 99%
“…2A, was recorded over 16 h using a 5 mM solution of a-hCG. The high quality of this spectrum was achieved by the combination of spoiler gradients and phase cycling to suppress pulse artifacts [16,26,32]. In Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Introduction of phase error is avoided in the 1D experiment through application of a selective x pulse; therefore, a phase correction factor is not required. 13 The 1D and 2D HSQMBC experiments provide excellent suppression of resonances arising from protons bound to 12 C.…”
Section: Brief Product Operator Description For the Hsqmbc Pulse Sequmentioning
confidence: 97%
“…The data are processed according to the echo-antiecho protocol to provide fully phase-sensitive data. 12 In the 1D version of this experiment, the evolution period is omitted and a symmetrical set of gradients with opposite amplitude (G 1 , G 2 ) surround a selective 13 C x pulse which substitutes the hard x pulse in the 2D experiment. The second gradient is followed by a similar 13 C /2 x -G 3 -1 H /2 x -υ-1 H x -G 4 pulse train as that used in the 2D experiment.…”
Section: Brief Product Operator Description For the Hsqmbc Pulse Sequmentioning
confidence: 99%
“…1 H and 13 C assignments were determined from two-dimensional 1 H total correlation spectroscopy experiments (30) using a 6-kHz spinlock for 256 complex increments and natural abundance 13 C, 1 H heteronuclear single quantum correlation experiment (31,32). All spectra were processed using VnmrJ 2.1B and 1 H and 13 C chemical shifts referenced to 2,2-dimethyl-2-silapentane-5-sulfonate sodium salt standard at 0.00 ppm.…”
Section: Primer Name Primer Sequencementioning
confidence: 99%