1979
DOI: 10.1088/0031-9155/24/2/011
|View full text |Cite
|
Sign up to set email alerts
|

Improved means of correcting motion blurring in scintigraphic images

Abstract: Various means of correcting gamma ray images for motion blurring have been investigated. An analogue circuit with unique features was developed which follows the movement of the centroid of an object distribution and stabilises the image display against any such movement.Motion correction with the centroid circuit will be of help in liver, spleen and kidney imaging.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

1979
1979
2007
2007

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…The central frequency shift (⌬ 0 ϭ ␥⌬B 0 ) can then be calculated using Eq. [6], and the image displacement after Fourier transformation can be obtained from Eq. [8].…”
Section: Phantom Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…The central frequency shift (⌬ 0 ϭ ␥⌬B 0 ) can then be calculated using Eq. [6], and the image displacement after Fourier transformation can be obtained from Eq. [8].…”
Section: Phantom Experimentsmentioning
confidence: 99%
“…The relationship between image displacement and ⌬ 0 ( ϭ ␥⌬B 0 ) was obtained from Eq. [6] and Eq. [8].…”
Section: Fmri Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Patient movements are a specific problem in the management of babies and children but may be troublesome also for non-collaborating patients or very long examinations. Movement corrections can be obtained with manual realignment of the frames, a technique which is not sufficiently precise and reproducible "per se", or by the use of anatomical markers superimposed on the images, which has limitations related both to the need of a large field-of-view (to encompass the markers themselves) and to the interference of the marker's activity with the radionuclide distribution (Barber 1982;McKeighen 1979;Vidiukov and Rotenberg 1982).…”
Section: Eur J Nucl Med (1992) 19:476-483mentioning
confidence: 99%
“…Moreover, because becomes large with an increase in frequency, the of the acoustic lens has a great effect on the sensitivity of a medical ultrasonic probe. 1) Silicone rubber has been the predominant externally focused acoustic lens material applied since 1970 2) because it is safe to use with the human body, has a suitable c (c $ 1000 m/s), and a reasonably low ( $ 0:3 dB mm À1 MHz À1 ). However, the of pure silicone rubber is approximately 0:97 Â 10 3 kg/m 3 .…”
Section: Introductionmentioning
confidence: 99%