2017
DOI: 10.1088/1367-2630/aa7e73
|View full text |Cite
|
Sign up to set email alerts
|

Improved limit on the directly measured antiproton lifetime

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
39
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(42 citation statements)
references
References 22 publications
1
39
0
1
Order By: Relevance
“…The application of voltage ramps to electrodes that interconnect the traps allows adiabatic shuttling of the particles between the traps. The electrode assembly is placed inside an indium-sealed trap can in which the low pressure enables antiprotons to be stored for years 19,29 . Each of the traps is equipped with a sensitive tuned circuit for non-destructive image current detection of the particles' axial oscillation frequencies at ν z ≈ 675 kHz (ref.…”
mentioning
confidence: 99%
“…The application of voltage ramps to electrodes that interconnect the traps allows adiabatic shuttling of the particles between the traps. The electrode assembly is placed inside an indium-sealed trap can in which the low pressure enables antiprotons to be stored for years 19,29 . Each of the traps is equipped with a sensitive tuned circuit for non-destructive image current detection of the particles' axial oscillation frequencies at ν z ≈ 675 kHz (ref.…”
mentioning
confidence: 99%
“…For the BASE analysis trap, ν + ≈ 17.845 MHz, ν − ≈ 10 kHz and ν z ≈ 675 kHz. The gold-plated OFHC electrodes are placed inside an indium-sealed vacuum chamber which is cooled to T ≈ 6 K. Cryo-pumping provides an ultra-high vacuum with pressures < 3 × 10 −18 mbar which enables storage times > 10 a [23]. Radio frequency (rf) lines equipped with high order low-pass and band-pass filters as well as high-insulation switches are used for particle manipulation ( Fig.…”
mentioning
confidence: 99%
“…A trapped ion polarizes neutral background gas atoms and thereby induces collisions described by the Langevin rate γ, which is proportional to the background gas density [35,42]. From our antiproton lifetime measurement [23] we derived upper limits for the partial pressure of hydrogen p upper,H < 1.2 × 10 −18 mbar and helium p upper,He < 2.7 × 10 −18 mbar leading to ζ + < 4 × 10 −9 s −1 . Voltage supply (UM1-14) noise at ν + is ruled out by independent measurements.…”
mentioning
confidence: 99%
“…Hence, while in order to increase statistical precision it is necessary to repeat measurements of f c ' and f z , measurements of f m are only needed to obtain and check the stability of δ. In Penning traps used for the most precise measurements, the chamber housing the electrodes is maintained at close to LHe temperature, resulting in extreme (<<10 −15 mbar) high-vacuum [19]. Hence single ions can be trapped and manipulated, and measurements made on them for many days.…”
Section: The Precision Penning Trapmentioning
confidence: 99%