1997
DOI: 10.1111/j.1699-0463.1997.tb05093.x
|View full text |Cite
|
Sign up to set email alerts
|

Improved ELISA for determination of anti‐diphtheria and/or anti‐tetanus antitoxin antibodies in sera

Abstract: and 2North American Vaccine Inc., Beltsville, USA Kristiansen, M., Aggerbeck, H. & Heron, I. Improved ELISA for determination of anti-diphtheria andlor anti-tetanus antitoxin antibodies in sera. APMIS 105: 843-853, 1997. Double-antigen ELISAs for detection and quantification of anti-tetanus or anti-diphtheria antibodies in serum have been developed. The assays showed good correlations with established toxin neutralizing assays and were functionally specific for IgG antibodies. The double-antigen set-up allo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
51
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 78 publications
(53 citation statements)
references
References 19 publications
1
51
0
1
Order By: Relevance
“…At the SSI, microtiter plates (MaxiSorp; Nunc, Roskilde, Denmark) were coated with 0.002 g of purified TT as previously described (19). The plates were incubated for 2 h at room temperature (RT, 20 to 25°C) with 4-fold serial dilutions of the serum samples (1:4 to 1:65,536) in dilution buffer consisting of phosphate-buffered saline (PBS; pH 7.4), 1% (vol/vol) Triton X-100, and 1% (wt/vol) bovine serum albumin (BSA).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…At the SSI, microtiter plates (MaxiSorp; Nunc, Roskilde, Denmark) were coated with 0.002 g of purified TT as previously described (19). The plates were incubated for 2 h at room temperature (RT, 20 to 25°C) with 4-fold serial dilutions of the serum samples (1:4 to 1:65,536) in dilution buffer consisting of phosphate-buffered saline (PBS; pH 7.4), 1% (vol/vol) Triton X-100, and 1% (wt/vol) bovine serum albumin (BSA).…”
Section: Methodsmentioning
confidence: 99%
“…Serosurveys could be used to monitor progress toward the achievement and maintenance of MNTE given challenges of reliably assessing TT coverage through vaccination history (14). For in vitro assays of tetanus seroprotection, gold standards are the DAE (double-antigen enzyme-linked immunosorbent assay [ELISA]) and toxin binding inhibition (ToBI) tests, which are not commercially available (15)(16)(17)(18)(19). Indirect tetanus ELISAs exist, but they overestimate antibody levels in the low seroprotective range (0.01 to 0.2 IU/ml) (15,(19)(20)(21).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Tetanus and diphtheria antibodies were tested using the double antigen ELISA, as described elsewhere (22). Measles antibodies were measured by indirect ELISA, as previously described (23).…”
Section: Detection Of Vaccine Antibodiesmentioning
confidence: 99%
“…Scobie et al (15) tout the DAE because with serum samples containing low levels of tetanus antitoxin (e.g., 0.01 to 0.14 IU/ ml), this method correlates well with established in vivo assays that measure protective neutralizing antitoxin levels (16). The same is true of the toxin binding inhibition assay for tetanus antitoxin determination (17).…”
mentioning
confidence: 97%