2006
DOI: 10.1016/j.aca.2005.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Improved analysis of membrane protein by PVDF-aided, matrix-assisted laser desorption/ionization mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 41 publications
0
11
0
Order By: Relevance
“…However, as for in-gel digestion, the recovery of large peptides was very low. An alternative approach directly analyzed the proteins or the peptides adsorbed onto the membrane by MALDI-MS [87]. In this approach, it is crucial that the matrix solution can dissolve the nitrocellulose-bound proteins or peptides in order for them to be incorporated into the matrix crystals.…”
Section: On-membrane Digestionmentioning
confidence: 99%
“…However, as for in-gel digestion, the recovery of large peptides was very low. An alternative approach directly analyzed the proteins or the peptides adsorbed onto the membrane by MALDI-MS [87]. In this approach, it is crucial that the matrix solution can dissolve the nitrocellulose-bound proteins or peptides in order for them to be incorporated into the matrix crystals.…”
Section: On-membrane Digestionmentioning
confidence: 99%
“…In a previous study, we demonstrated that PVDF-aided MALDI-TOF MS can be an effective approach for improvement of the spot-to-spot variation in MALDI detection and profiling and characterizing membrane proteins [31]. Compared with the standard metallic MALDI sample plate, both intensity and S/N ratio were greatly improved in MALDI mass spectra by using PVDF membrane.…”
Section: Introductionmentioning
confidence: 99%
“…Chang et al [29] separated membrane proteins from gram-negative bacteria by SDS ⁄ PAGE, electroblotted the proteins onto the Hybond-P PVDF membranes and then fixed the membrane to the sample target using conductive double-sided adhesive tape. The matrix for MALDI-TOF MS was added to the samples for MS analysis.…”
Section: Membrane Namementioning
confidence: 99%
“…Therefore, it was necessary to develop new membranes on which digests of the immobilized protein can be ionized efficiently. Without this improvement, peptides obtained by on-membrane digestion of gel-resolved proteins would have to be eluted from the membrane and then subjected to MALDI for identification [25][26][27][28][29][30].…”
Section: Small Pore Size Of Membrane Increases Ion Yield In Msmentioning
confidence: 99%