2015
DOI: 10.1016/j.arth.2015.02.027
|View full text |Cite
|
Sign up to set email alerts
|

Important Differences Exist in Posterior Condylar Offsets in an Osteological Collection of 1,058 Femurs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
17
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 34 publications
(59 reference statements)
2
17
2
Order By: Relevance
“…Furthermore, it is considered to be a strength of the present study that not only the variability in PFO and DCO was shown, but also in AP and ML measurements. Weinberg et al [26], who measured the PCO of 1058 femurs, support our findings with a further statement that the PCO varies not only among individuals, but also within individuals. Surgeons should be aware of this fact when doing bilateral TKA.…”
Section: Discussionsupporting
confidence: 91%
“…Furthermore, it is considered to be a strength of the present study that not only the variability in PFO and DCO was shown, but also in AP and ML measurements. Weinberg et al [26], who measured the PCO of 1058 femurs, support our findings with a further statement that the PCO varies not only among individuals, but also within individuals. Surgeons should be aware of this fact when doing bilateral TKA.…”
Section: Discussionsupporting
confidence: 91%
“…42 There were no gender differences present in the maximal trochlear depth, a result similar to the findings of Pinskerova et al, who found no sex differences existed in trochlear depth measurements standardized for femoral size. 43 While racial differences in distal femur geometry have been described for other parameters, 17 we are unaware of any literature comparing trochlear depth between races. Referenced from the vertical: a beam oriented directly vertically corresponds to a beam orientation of 0 degrees.…”
Section: Discussionmentioning
confidence: 99%
“…Using a previously described mathematical technique for modeling the distal femur, basic formulae were used to calculate the maximum trochlear depth using an average of medial and lateral flange depths based on a linearly weighted average for the position of the trochlear grove relative to each flange. 17 The MicroScribe 3D has a positional accuracy of 0.43 mm and a positional resolution of 0.13 mm, according to official documentation provided by the manufacturer. All digitizer measurements were performed by a single individual, with another individual performing interexperimenter reliability on five specimens (150 measurements in total).…”
Section: Measuring Trochlear Depth Osteologically With a Microscribe mentioning
confidence: 99%
“…Though UKA has undergone periods of criticism since its inception, namely, questioning its survival in comparison to TKA [ 4 , 5 ], it may offer faster recovery [ 6 , 7 , 8 ], reduced complication rates [ 7 , 8 , 9 , 10 ], improved patient-reported functional outcomes [ 11 , 12 , 13 ], and a more normal feeling knee [ 14 , 15 ] in appropriately selected patients. The importance of continuing to study UKA and its technological developments is highlighted by the significant and increasing healthcare burden that osteoarthritis (OA) poses across the world and the increasing number of patients with OA-related knee disorders who seek to maintain a high level of activity [ 16 , 17 , 18 , 19 ].…”
Section: Introductionmentioning
confidence: 99%
“…In contrast to the traditional method of selecting implant size and geometry from an available set of options, these implants are manufactured on an individual basis from a three-dimensional rendering of pre-operative computed tomography (CT) imaging. Their development originated from the high variability seen in distal femoral and proximal tibial bone geometry [ 16 , 17 , 18 , 19 ], as well as the increasing focus on restoring the natural knee anatomy with arthroplasty in recent years [ 20 , 21 ]. In theory, a closer approximation of the natural anatomy would provide for improved kinematics, as shown in customized TKA (C-TKA) [ 22 , 23 ].…”
Section: Introductionmentioning
confidence: 99%