Implementation of LYSO/PSPMT Block Detector With All Digital DAQ System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 31 publications
(25 citation statements)
references
References 36 publications
0
25
0
Order By: Relevance
“…According to the manufacturer of PET block detector, 1.0 mm-diameter rods can be clearly resolved [28], while FWHMs along x, y, and z axis at the center of FOV of our PET sub-system are 1.139 mm, 1.750 mm, and 2.959 mm, respectively. The reconstructed Derenzo phantom image showed consistency with the results calculated from FWHM, which verified the spatial resolution of PET sub-system was between 1.2 mm and 1.6 mm.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…According to the manufacturer of PET block detector, 1.0 mm-diameter rods can be clearly resolved [28], while FWHMs along x, y, and z axis at the center of FOV of our PET sub-system are 1.139 mm, 1.750 mm, and 2.959 mm, respectively. The reconstructed Derenzo phantom image showed consistency with the results calculated from FWHM, which verified the spatial resolution of PET sub-system was between 1.2 mm and 1.6 mm.…”
Section: Discussionmentioning
confidence: 97%
“…A high-speed, low-noise CMOS X-ray detector (1512, Dexela, London, UK) was placed on the direction of 225°, opposite to the Xray tube. Four PET block detectors (Raycan Technology, Suzhou, China) [28] were fixed on four electrical linear guideways on the directions of 0°, 90°, 180°, and 270°, respectively. A back-illuminated electron-multiplying charge-coupled device (EMCCD, iXon 888, Andor, Belfast, UK) camera was chosen to collect visual/infrared photons and produce optical images for BLT, FMT, and CLT.…”
Section: Instrumentations Of the Pet/blt/fmt/clt/ct Pentamodal Imaginmentioning
confidence: 99%
“…TDC and the proposed energy calibration method are realized in a field programmable gate array(FPGA). The digital samples are sent to personal computer(PC) via Ethernet, and the scintillation pulse is reconstructed with a model formulated as a straight line followed by an exponential decay [2]. To reduce the error of pulse fitting, only the scintillation pulse with its amplitude larger than 3 voltage thresholds are used for reconstruction.…”
Section: Methodsmentioning
confidence: 99%
“…Digitizing scintillation pulses with the Multi-voltage threshold(MVT) method shows great potentials for building all-digital positron emission tomography (PET) [2]. An accurate pulse model used Manuscript for pulse fitting is a critical factor to precisely reconstruct the pulse in the MVT method.…”
Section: Introductionmentioning
confidence: 99%
“…A 14 × 14 tapered light-guide was designed to deliver the photons from 18 × 18 LYSO crystals into the PSPMT [9,10]. The top entrance size of the light-guide remains the same with the scintillator array crystal area (23.5 × 23.5 mm 2 ).…”
Section: Modular Construction Of the Pet Detectormentioning
confidence: 99%