2018
DOI: 10.1016/j.ajo.2017.12.015
|View full text |Cite
|
Sign up to set email alerts
|

Implantable Collamer Lens Sizing Method Based on Swept-Source Anterior Segment Optical Coherence Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
96
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 106 publications
(100 citation statements)
references
References 24 publications
3
96
0
1
Order By: Relevance
“…34 Although the central vault did not differ between eyes with and without cysts, the average vault in eyes presenting cysts was 100 μm higher than in the eyes without cysts. Considering these arguments, the current vault prediction formulas 7 – 11 which are solely based on preoperative biometry and lens parameters, may require the introduction of additional factors characterizing the postoperative resting position of the lens. Currently, not considering the postoperative position of the ICL nor particular characteristics in the posterior chamber anatomy, the prediction of the vault in eyes with similar anatomy is limited to 81%.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…34 Although the central vault did not differ between eyes with and without cysts, the average vault in eyes presenting cysts was 100 μm higher than in the eyes without cysts. Considering these arguments, the current vault prediction formulas 7 – 11 which are solely based on preoperative biometry and lens parameters, may require the introduction of additional factors characterizing the postoperative resting position of the lens. Currently, not considering the postoperative position of the ICL nor particular characteristics in the posterior chamber anatomy, the prediction of the vault in eyes with similar anatomy is limited to 81%.…”
Section: Discussionmentioning
confidence: 99%
“…The need for predicting the vault has led to the development of predictive models using biometric and lens features. 7 – 11 Despite the variety of associations put forward, the ability of explaining the vault preoperatively is limited to approximately 40% 9 , 10 and decreases to 14% if the prediction is restricted to an optimal vault range. 12 Several arguments have been presented to justify the limited predictability of the models.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, we speculated that pupil constriction due to the disappearance of the effect of the mydriatic agent played a very important role in vault reduction within 1 day after surgery. Finally, several studies have proven that the morphology of the crystalline lens also has an in uence on vault after ICL implantation [32][33][34]. ICL vault was affected by changes in crystalline lens rise (CLR) caused by accommodation or light condition changes [20,35,36].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, OCT measurements have been shown to be useful for size calculation of posterior chamber phakic lenses, such as the implantable collamer lens [35]. This may help avoid excessive vaulting of such IOLs as well as touching of the IOL to the crystalline lens.…”
Section: Ss-oct Measurements Of the Crystalline Lensmentioning
confidence: 99%