2022
DOI: 10.1186/s12886-022-02583-9
|View full text |Cite
|
Sign up to set email alerts
|

Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula

Abstract: Background To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. Methods This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperativel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(13 citation statements)
references
References 31 publications
(35 reference statements)
0
13
0
Order By: Relevance
“…Personalized ICL size selection considers the anterior chamber structure, including the accurate measurement of LT. Additionally, LT is an essential parameter for predicting post-ICL vault height. [25,26] The WTW measured using the Colombo IOL was signi cantly in agreement (ICC:0.729, p < 0.0001) with IOL master 700 but with larger readings (β = -0.244, p < 0.0001). An average deviation of -0.244 mm for WTW (with a 95% LOA from − 0.603 mm to 0.114 mm, p < 0.0001) was also observed from the Bland-Altman plots.…”
Section: Discussionmentioning
confidence: 95%
“…Personalized ICL size selection considers the anterior chamber structure, including the accurate measurement of LT. Additionally, LT is an essential parameter for predicting post-ICL vault height. [25,26] The WTW measured using the Colombo IOL was signi cantly in agreement (ICC:0.729, p < 0.0001) with IOL master 700 but with larger readings (β = -0.244, p < 0.0001). An average deviation of -0.244 mm for WTW (with a 95% LOA from − 0.603 mm to 0.114 mm, p < 0.0001) was also observed from the Bland-Altman plots.…”
Section: Discussionmentioning
confidence: 95%
“…It incorporates the Zhang and Zheng (ZZ) ICL formula and relies on LT, vertical STS, and horizontal STS to predict vault and calculate IOL size. 24 …”
Section: Planning Methodsmentioning
confidence: 99%
“… The KS formula is based on ICL size and ATA for the prediction of vault; the predicted vault values were automatically obtained from CASIA2 AS-OCT [ 12 ]. The ZZ formula, based on HSTS, VSTS, and LT for the prediction of vault; predicted vault values were obtained by utilizing data from the website ( http://www.zzcal.com ) [ 15 ]. The WH formula is based on the ICL size, ATA, CLR, and CSA for vault prediction.…”
Section: Methodsmentioning
confidence: 99%