2007
DOI: 10.1243/09544097f02105
|View full text |Cite
|
Sign up to set email alerts
|

Impact of overhead line irregularity on current collection and diagnostics based on the measurement of pantograph dynamics

Abstract: As train speed increases, contact wire irregularity affects the quality of current collection more and more. The possibility of achieving the maximum operating speed depends also on the maintenance level of the overhead line (OHL). In the present paper, the influence of contact wire irregularity (in terms of vertical deviation of its position) is investigated both experimentally and by means of numerical simulation of the dynamic interaction of pantograph and catenary. In a first step, the capability of the si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
41
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(41 citation statements)
references
References 3 publications
0
41
0
Order By: Relevance
“…In fact, due to the variation of contact wire elasticity along the catenary, the CSWs generally occupy a large proportion of energy in PCCF, which makes other signal components that may be caused by anomalies such as contact wire irregularity [14], contact strip wear [16], environmental perturbation [17], etc. almost unobservable.…”
Section: Introductionmentioning
confidence: 99%
“…In fact, due to the variation of contact wire elasticity along the catenary, the CSWs generally occupy a large proportion of energy in PCCF, which makes other signal components that may be caused by anomalies such as contact wire irregularity [14], contact strip wear [16], environmental perturbation [17], etc. almost unobservable.…”
Section: Introductionmentioning
confidence: 99%
“…Collina et al [125] analyzed the influences of contact wire irregularity on the current collection based on in situ measurements combining with simulation results. The pantograph vertical acceleration is employed to reflect and diagnose the state of contact wire irregularity.…”
Section: Static State Evaluation Of Catenary Systemmentioning
confidence: 99%
“…Basic parameters of the adopted sensors are described in Table I, where FS denotes the sensor full scale and g is the gravitational acceleration. The results of contact force are corrected as required by (1).…”
Section: Data Measurement and Pre-processingmentioning
confidence: 99%
“…In most of the electrified railways, vehicles receive traction current through the sliding contact between pantograph and catenary above the roof. Due to the intrinsic characteristics of the pantograph-catenary system and various environmental disturbances [1], the contact force between pantograph and catenary fluctuates during operation and determines the current collection quality. Therefore, even expensive, a reliable health condition monitoring technology for the pantograph-catenary system often adopts the contact force as the key measurement parameter to assess the dynamic interaction and eventually the current collection quality [2].…”
Section: Introductionmentioning
confidence: 99%