2021
DOI: 10.1088/1361-6498/ac0d63
|View full text |Cite
|
Sign up to set email alerts
|

Impact of new operational dosimetric quantities on individual monitoring services

Abstract: The new operational dosimetric quantities framework, proposed in the ICRU95 report, has stimulated the scientific community to start investigations that aim to assess its impact on radiation protection practices. As part of this effort, the present study describes an inter-comparison exercise among individual monitoring services (IMSs) on passive whole-body dosimetry. The inter-comparison is performed in terms of both the existing operational dose quantity … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…To improve the accuracy of the new definition response, the system can be modified to an accurate response by simply applying an energy-independence correction factor [8] or by using a new algorithm for the dose calculation. Both methods include no changes to the filters or the design of the badges.…”
Section: Data Analysis For Transformation Of Old To New Definitionmentioning
confidence: 99%
“…To improve the accuracy of the new definition response, the system can be modified to an accurate response by simply applying an energy-independence correction factor [8] or by using a new algorithm for the dose calculation. Both methods include no changes to the filters or the design of the badges.…”
Section: Data Analysis For Transformation Of Old To New Definitionmentioning
confidence: 99%
“…Focusing on the operational quantities used by the monitoring instrumentation, the ICRU recently presented new definitions in the case of external radiation, improving the methodology for estimating the effective dose and promoting its gradual adoption [ 7 ]. The influence of these novelties must be investigated from the point of view of radiation emergency monitoring: the new operational quantities should allow for a more accurate estimation of the effective dose and dose to the extremities, but relevant differences remain for some photon and neutron fields [ 11 , 12 , 13 ].…”
Section: From Sievert To Graymentioning
confidence: 99%
“…Pozzi et al [5] studied the impact of switching to the new quantity ambient dose, H * in two neutron reference fields and in a high-energy workplace field. Another study by Caresana et al [6] compared the existing operational dose quantity H p (10) with its proposed replacement H p in reference fields at standard beam qualities, to assess if actions may be necessary to adapt dosimetry systems to the new quantity. Eakins et al [7] studied the impact of the new operational dose quantities on the response characteristics of a beta/gamma personal dosimeter.…”
Section: Introductionmentioning
confidence: 99%