Abstract: Abstract-This paper evaluates the impact of load dynamics on torsional interactions by considering a mix of static and dynamic loads aggregated at the bulk transmission level. This is essential to investigate the importance of detailed load modelling for subsynchronous resonance (SSR) studies to accurately assess damping contribution and capture system dynamics. SSR interaction with dynamic loads is investigated for both direct on line and drive connected motor loads. Damping contribution from dynamic loads is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…About ∼80% of the total industrial machine loads are operated as DOL starting mode [32]. In DOL start motors, the stator of the IM is directly connected to the network, hence any voltage/frequency deviations at the motor terminal makes motor vulnerable to instability [33, 34]. With the development of power electronics technology, VFD plays an important role in IM control, and VFD‐based IMs will constitute a significant share in the near future.…”
Section: Im Oscillations and Damping Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…About ∼80% of the total industrial machine loads are operated as DOL starting mode [32]. In DOL start motors, the stator of the IM is directly connected to the network, hence any voltage/frequency deviations at the motor terminal makes motor vulnerable to instability [33, 34]. With the development of power electronics technology, VFD plays an important role in IM control, and VFD‐based IMs will constitute a significant share in the near future.…”
Section: Im Oscillations and Damping Analysismentioning
confidence: 99%
“…A 100 kW diesel generator is directly connected to the PCC of the AC sub‐grid of the AC/DC hybrid microgrid. About ∼80% of the residential and industrial motor is DOL start type [34], hence two 150 kW DOL start IMs are used as the dynamic load in the hybrid AC/DC microgrid, which amounts to 37.50% of the total load at the AC sub‐grid.…”
Section: Detail Description Of the Test Systemmentioning
confidence: 99%