2002
DOI: 10.1016/s0142-9612(01)00289-7
|View full text |Cite
|
Sign up to set email alerts
|

Immobilization of a nonsteroidal antiinflammatory drug onto commercial segmented polyurethane surface to improve haemocompatibility properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
0
1

Year Published

2003
2003
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(23 citation statements)
references
References 59 publications
(55 reference statements)
1
21
0
1
Order By: Relevance
“…[32,33] Adsorption of fibrinogen from the blood is known to accelerate platelet adhesion and formation of thrombosis on foreign surfaces which show low binding amounts for fibrinogen are more biocompatible. [34][35][36] According to our results, the silicon wafer, the undoped, and the doped SiNWs have quite low fibrinogen adsorption values, demonstrating that they are quite heamocompatible. We note that on the fibrinogen column, first line is the amount of free fibrinogen in the plasma and others indicate the amount of adsorbed fibrinogen on the Si wafer, the undoped, and doped SiNW surfaces.…”
Section: Heamocompatibilitymentioning
confidence: 97%
“…[32,33] Adsorption of fibrinogen from the blood is known to accelerate platelet adhesion and formation of thrombosis on foreign surfaces which show low binding amounts for fibrinogen are more biocompatible. [34][35][36] According to our results, the silicon wafer, the undoped, and the doped SiNWs have quite low fibrinogen adsorption values, demonstrating that they are quite heamocompatible. We note that on the fibrinogen column, first line is the amount of free fibrinogen in the plasma and others indicate the amount of adsorbed fibrinogen on the Si wafer, the undoped, and doped SiNW surfaces.…”
Section: Heamocompatibilitymentioning
confidence: 97%
“…Films were prepared by the solution casting from the solutions of the mixtures. The solvent was slowly evaporated at room temperature for 2 days in a desiccator cabinet followed by vacuum drying overnight at 60 o C. The crosslinking reaction was performed by heating the film in a vacuum oven at 120 o C for 3 h. 7 In the preliminary experiment, it was found that the viscosity of blends containing above 40 wt% of MPU was too high to control film thickness and smoothness. The simple blends films containing above 40 wt% of MPU were found to be dissolved completely in water at 37 o C within 48 h. The MPU content should be higher to improve the properties of blends.…”
Section: Methodsmentioning
confidence: 99%
“…[1][2][3][4][5][6] Although many successful results have been obtained when using polyurethanes in different biomedical devices, such as vascular prostheses, heat valves, blood pumps and artificial hearts, the inherent thrombogenicity of segmented polyurethanes has been a problem. 7 Therefore, the development of non-thrombogenic biomaterials has remained one of the most elusive challenges in biomaterial field.…”
Section: Introductionmentioning
confidence: 99%
“…Although many successful results have been obtained when using polyurethanes in different biomedical devices, such as vascular prostheses, heart valves, blood pumps, and artificial hearts, the inherent thrombogenicity of segmented polyurethanes has a problem [7]. Therefore, the development of non-thrombogenic biomaterials has remained one of the most elusive challenges in biomaterial science for decades.…”
Section: Introductionmentioning
confidence: 99%