Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2020
DOI: 10.3389/fcvm.2020.00060
|View full text |Cite
|
Sign up to set email alerts
|

Imaging and Patient Selection for Transcatheter Tricuspid Valve Interventions

Abstract: With the emergence of transcatheter solutions for the treatment of tricuspid regurgitation (TR) increased attention has been directed to the once neglected tricuspid valve (TV) complex. Recent studies have highlighted new aspects of valve anatomy and TR etiology. The assessment of valve morphology along with quantification of regurgitation severity and RV function pose several challenges to cardiac imagers guiding transcatheter valve procedures. This review article aims to give an overview over the role of mod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 109 publications
(144 reference statements)
0
9
0
1
Order By: Relevance
“…Its compression needs to be avoided when securing devices to the tricuspid annulus ( 76 ). Calcification along the annulus can also impair percutaneous valve deployment, which can be detected pre-procedurally via CT ( 77 ).…”
Section: Ct For Guiding Transcatheter Tricuspid Valve Interventionmentioning
confidence: 99%
“…Its compression needs to be avoided when securing devices to the tricuspid annulus ( 76 ). Calcification along the annulus can also impair percutaneous valve deployment, which can be detected pre-procedurally via CT ( 77 ).…”
Section: Ct For Guiding Transcatheter Tricuspid Valve Interventionmentioning
confidence: 99%
“…The choice of the most suitable transcatheter therapeutic option in a single patient remains challenging ( 38 , 39 ). This is because the implantation of a device within the tricuspid annulus is challenged by the variable anatomy of the TV, very thin leaflets, and the anatomic proximity to other structures (coronary sinus, His bundle, atrioventricular node, and RCA).…”
Section: Anatomic Considerations For Interventionsmentioning
confidence: 99%
“…Although advanced cardiac imaging with echocardiography, cardiac computed tomography, and magnetic resonance imaging provide unique opportunities to study the valvular apparatus, imaging can sometimes be challenging and lack the spatial resolution for detailed anatomic definition [3]. Further, normal human valves are difficult to obtain for anatomical dissection.…”
Section: Introductionmentioning
confidence: 99%