In type 2 diabetes, anti-thrombotic management is challenging, and current anti-platelet agents have demonstrated reduced efficacy. Old and new anti-diabetic drugs exhibited—besides lowering blood glucose levels—direct and indirect effects on platelet function and on thrombotic milieu, eventually conditioning cardiovascular outcomes. The present review summarizes existing evidence on the effects of glucose-lowering agents on platelet properties, addressing pre-clinical and clinical research, as well as drug–drug interactions with anti-platelet agents. We aimed at expanding clinicians’ understanding by highlighting new opportunities for an optimal management of patients with diabetes and cardiovascular disease. We suggest how an improvement of the thrombotic risk in this large population of patients may be achieved by a careful and tailored combination of anti-diabetic and anti-platelet therapies.
Nowadays, severe symptomatic tricuspid regurgitation (TR) affects millions of persons worldwide. However, the benefit of surgical correction of isolated secondary TR remains controversial because of the increased risk of periprocedural mortality and morbidity. In recent years, novel transcatheter tricuspid valve interventions (TTVI) were developed to treat TR, so that TTVI is currently considered in symptomatic, inoperable, anatomically eligible patients. TTVI can be divided into these five domains: edge-to-edge leaflet repair, tricuspid annuloplasty, caval implants, spacer, and total valve replacement. Each transcatheter intervention needs specific imaging protocols for assessing the anatomical feasibility and consequentially predicting the procedural success. This review summarizes the available multimodality imaging tools for screening patients with TR, and identifies anatomical characteristics to choose the best option for the patient.
Background: Computed tomography (CT) is the recommended imaging technique for defining the anatomical suitability for current transcatheter technologies and planning tricuspid valve (TV) intervention. The aim of the Tricuspid Regurgitation IMAging (TRIMA) study was to assess the geometrical characteristics of the TV complex using novel CT parameters. Methods: This prospective, single-center study enrolled 22 consecutive patients with severe tricuspid regurgitation, who underwent a cardiac CT study dedicated to the right chambers. The following variables were obtained: annulus area and perimeter, septal-lateral and antero-posterior diameters, tenting height, and anatomical regurgitant orifice area. Moreover, the following novel annular parameters were assessed: distance between commissures, distance between TV centroid and commissures, and angles between centroid and commissures. Results: A significant phasic variability during the cardiac cycle existed for all variables except for eccentricity, angles, and distance between the postero-septal and antero-posterior commissure and distance between the centroid and antero-posterior commissure. There was a significant relationship between the TV annulus area and novel annular parameters, except for annular angles. Additionally, novel annular variables were found to predict the annulus area. Conclusions: These novel additional variables may provide an initial platform from which the complexity of the TV annular morphology can continue to be better understood for further improving transcatheter therapies.
In past cardiovascular medicine, the attention to the left ventricle-identified as the only indicator and determinant of healthy or unhealthy cardiac conditions- has systematically hidden the role of the left atrium (LA). The recent advances in cardiovascular imaging have provided a better understanding of LA anatomy, physiology, and pathology, making us realize that this functional structure is far from being an innocent spectator. We now know that the LA's mechanical and neuro-hormonal properties play a relevant part in several cardiovascular diseases, including atrial fibrillation, ischemic heart disease, valvular heart disease, and heart failure. The present review aims to describe the role of LA in the specific setting of heart failure. We provide currently available information on LA structure and function and summarize its role as a determinant of symptoms, prognosis, and potential therapeutic target in heart failure patients.
Coronavirus disease 2019 (COVID-19) is known to present with respiratory symptoms, which can lead to severe pneumonia and respiratory failure. However, it can have multisystem complications such as cardiovascular manifestations. The cardiovascular manifestations reported comprise myocarditis, cardiogenic shock, arrhythmias, pulmonary embolism, deep vein embolism, acute heart failure, and myocardial infarction. There is also an indirect impact of the pandemic on the management of cardiovascular care that has been shown clearly in multiple publications. In this review, we summarize the deadly relation of COVID-19 with cardiovascular events and the wider impact on several cardiovascular care areas by the pandemic situation
Background Twelve-lead ECG represents the most common diagnostic tool in clinical cardiology and allows an immediate screening of left ventricular hypertrophy (LVH), but current criteria might have poor clinical usefulness in everyday clinical practice due to lack of sensitivity. Methods The current study aims to review and compare the clinical performance of known ECG criteria of LVH in a real-life setting; 2134 patients had ECG and echocardiographic exams performed during the same hospitalization. All traces were retrospectively analysed, and the amplitudes of the waves were manually measured. Transthoracic echocardiography was considered as the gold standard to assess LVH. Results LVH had a prevalence of 58%. Considering the diagnostic performance of ECG criteria for LVH, the Cornell voltage carried the best area under the receiver operating characteristic curve (0.678), while RaVF (R wave in aVF lead) had the poorer result (0.440). The R5/R6 criterion had the best sensitivity (60%), but with the worst specificity (37.4%). The ‘Q or S aVR’ had the best specificity (99.9%) but lacks sensitivity (0.80%). The Peguero Lo Presti criterion had a sensitivity of 42.3% and a specificity of 75.8%. The Cornell voltage and the Cornell product had similar area under the receiver operating characteristic curve values which were found to be significantly greater compared with other criteria. Conclusion Current ECG criteria of LVH have low sensitivity despite an acceptable specificity. Among these, Cornell voltage and Cornell product criteria were equally found to have a more accurate diagnostic performance compared with other criteria. To overcome the intrinsic limitations of the current ECG LVH criteria, a new paradigm in the analysis of electrocardiographic data might be necessary.
Contemporary anticancer immunotherapy with chimeric antigen receptor T-cell (CAR-T) therapy has dramatically changed the treatment of many hematologic malignancies previously associated with poor prognosis. The clinical improvement and the survival benefit unveiled the risk of cardiotoxicity, ranging from minimal effects to severe cardiac adverse events, including death. Immunotherapy should also be proposed even in patients with pre-existing cardiovascular risk factors, thereby increasing the potential harm of cardiotoxicity. CAR-T therapy frequently results in cytokine release syndrome (CRS), and inflammatory activation is sustained by circulating cytokines that foster a positive feedback mechanism. Prompt diagnosis and treatment of CAR-T cardiotoxicity might significantly improve outcomes and reduce the burden associated with cardiovascular complications. Clinical and echocardiographic examinations are crucial to perform a tailored evaluation and follow-up during CAR-T treatment. This review aims to summarize the pathophysiology, clinical implications, and echocardiographic assessment of CAR-T-related cardiotoxicity to enlighten new avenues for future research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.