2019
DOI: 10.1259/dmfr.20190032
|View full text |Cite
|
Sign up to set email alerts
|

Image quality optimization of narrow detector dental computed tomography for paediatric patients

Abstract: Objectives: Dental CBCT exposure parameters should be optimized according to patient-specific indications, mainly for children that are most vulnerable to harmful effects of ionizing radiation. The aim of this study was to determine optimized kV settings for paediatric acquisitions for a dental CBCT device. Methods: Clinical and quantitative evaluations of image quality were performed using 5 and 10 years old (y/o) anthropomorphic phantoms. Technical evaluation was performed with the SEDENTEXCT-IQ phantom. Ima… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…Such artefacts may be caused by high dense materials, such as ceramic restoration materials, sealers, yet also by enamel in the region of the crown but not the root. 18 Such artifact expression may further increase by motion [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
“…Such artefacts may be caused by high dense materials, such as ceramic restoration materials, sealers, yet also by enamel in the region of the crown but not the root. 18 Such artifact expression may further increase by motion [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
“…This allowed to overcome the observer variability and bias associated with dynamic analysis of CBCT images. Even though static image analysis does not represent a clinical norm where images are assessed by dynamic scrolling, it is the most plausible part of methodologies where subjective image quality assessment is the point of interest 11 , 22 24 .…”
Section: Discussionmentioning
confidence: 99%
“…The selection of the appropriate imaging examination for the TMJ should be performed with caution [1], with the most appropriate clinical presentation, using low-dose protocols [7], improving the diagnosis [1], and in accordance with the 'As Low As Diagnostically Acceptable' principle [7]. There is a high potential to reduce radiation doses in CBCT, maintaining adequate image quality for diagnosis [8][9][10][11][12][13]. TMJ structures, for example, have the advantage of presenting a relatively high contrast in CBCT scans.…”
Section: Introductionmentioning
confidence: 99%