Image quality dependence on in-plane positions and directions for MDCT images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
11
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…This drop in resolution as a function of distance from the centre is likely caused by the finite number of views and focal spot size. In UHRCT, the relative drop in resolution is comparable to that of other systems [17][18][19].…”
Section: Discussionmentioning
confidence: 83%
See 1 more Smart Citation
“…This drop in resolution as a function of distance from the centre is likely caused by the finite number of views and focal spot size. In UHRCT, the relative drop in resolution is comparable to that of other systems [17][18][19].…”
Section: Discussionmentioning
confidence: 83%
“…The CT numbers resulted from different materials and scan modes. Used phantoms and expected range by the ACR[17] is given in the last column Images of the Catphan low-contrast objects in the CTP515 module acquired in NR, HR and SHR modes of the UHRCT and on the MDCT (left) at a CTDI vol of 9.1 mGy and (right) for the same low-contrast detectability, the CTDI vol is noted. Note that the window width is not the same for all images; for the SHR and HR modes, it is 60 (left) and 50 (right) and for the NR and MDCT it is 30…”
mentioning
confidence: 99%
“…Detailed methodologies for the wire and bead methods have not been investigated for currently available MDCT. In a typical approach for MTF determination, (7–9,13–19) the LSF is first obtained by processing the wire/bead image data. In the present study, to determine the LSF, the square‐shaped ROI was integrated and the obtained data were then offset‐corrected and normalized (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…To evaluate the image sharpness in the scan plane, MTF measurements are performed by using a phantom such as point source, (7–9) line pair, (10) edge, (11) as well as others (12) . Methods that use a point source phantom, such as a thin wire or a microbead, are most widely utilized in current CT systems (13–20) as they are conceptual simplicity and relatively easy to implement. When using such methods, in a typical approach for determination of MTF, (7–9,12–19) the line spread function (LSF) is first obtained by processing the scanned image (Fig.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation