Background: The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. Aims: This report offers updated testing guidelines for testing CT systems with an enhanced focus on the operational performance including iterative reconstructions and automatic exposure control (AEC) techniques. Materials and Methods: The report was developed based on a comprehensive review of best methods and practices in the scientific literature. The detailed methods include the assessment of 1) CT noise (magnitude, texture, nonuniformity, inhomogeneity), 2) resolution (task transfer function under varying conditions and its scalar reflections), 3) task-based performance (detectability, estimability), and 4) AEC performance (spatial, noise, and mA concordance of attenuation and exposure modulation). The methods include varying reconstruction and tube current modulation conditions, standardized testing protocols, and standardized quantities and metrology to facilitate tracking, benchmarking, and quantitative comparisons. Results: The methods, implemented in cited publications, are robust to provide a representative reflection of CT system performance as used operationally in a clinical facility. The methods include recommendations for phantoms and phantom image analysis. Discussion: In line with the current professional trajectory of the field toward quantitation and operational engagement, the stated methods offer quantitation that is more predictive of clinical performance than specification-based approaches. They can pave the way to approach performance testing of new CT systems not only in terms of acceptance testing (i.e., verifying a device meets predefined specifications), but also system commissioning (i.e., determining how the system can be used most effectively in clinical practice). Conclusion: We offer a set of common testing procedures that can be utilized towards the optimal clinical utilization of CT imaging devices, benchmarking across varying systems and times, and a basis to develop future performance-based criteria for CT imaging.
In x-ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x-ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual-energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low-and high-tube potential scans, fast tube-potential switching, beam filtration combined with spiral scanning, dual-source, or dual-layer detector approaches. The use of energy-resolving, photon-counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual-energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast-enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual noncontrast-enhanced images from contrast-enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric-acid and non-uric-acid urinary stones or uric acid (gout) or non-uric-acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.
Dose reduction efforts in diagnostic CT have brought the tradeoff of dose versus image quality to the forefront. The need for meaningful characterization of image noise beyond that offered by pixel standard deviation is becoming increasingly important. This work aims to study the implementation of the noise power spectrum (NPS) and noise equivalent quanta (NEQ) on modern, multislice diagnostic CT scanners. The details of NPS and NEQ measurement are outlined and special attention is paid to issues unique to multislice CT. Aliasing, filter design and effects of acquisition geometry are investigated. While it was found that both metrics can be implemented in modern CT, it was discovered that NEQ cannot be aptly applied with certain non-traditional reconstruction filters or in helical mode. NPS and NEQ under a variety of conditions are examined. Extensions of NPS and NEQ to uses in protocol standardization are also discussed.
In the current study, the effects of reconstruction algorithms on quantitative measures derived from computed tomographic (CT) lung images were assessed in patients with emphysema. CT image data sets were reconstructed with a standard algorithm and alternative algorithm(s) for 42 subjects. Algorithms were grouped as overenhancing, sharp, standard, or smooth. Density mask and volume measurements from the alternative algorithm data sets were compared with standard algorithm data sets. The overenhancing category yielded an average shift of 9.4% (ie, a shift in average score from 35.5% to 44.9%); the sharp category, a shift of 2.4%; and the smooth category, a shift of -1.0%. Differences in total lung volume measurements were less than 1%. In conclusion, the CT reconstruction algorithm may strongly affect density mask results, especially for certain reconstruction algorithms.
Balancing dose and image quality requires signal-to-noise (SNR) metrics which incorporate both the variance and the spatial frequency characteristics of noise. In this study, the non-prewhitening matched filter SNR metric is calculated for 2 mm slices of a 1 cm diameter sphere under three different conditions: (1) constant pixel standard deviation, (2) constant dose and (3) constant reconstruction filter. For the constant pixel standard deviation condition, an increase of 260% in SNR was found with increasing filter sharpness. For constant dose, the SNR remained level for smooth to medium filters, then declined by up to 55% with increasing filter sharpness. For a constant reconstruction filter, the SNR increased with dose, but not as high as photon statistics would predict. However, when structured noise was removed from the noise power spectrum, the SNR did vary with quanta statistics. These results offer protocol design guidance for low-frequency-dominated objects.
Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10-1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four cross-section datasets as well as the tally method for collision kerma versus absorbed dose. The total photon attenuation coefficient cross-section for low atomic number elements has changed significantly as cross-section data have changed between 1967 and 1989. Differences of up to 10% are observed in the photoelectric cross-section for water at 30 keV between the standard MCNP cross-section dataset (DLC-200) and the most recent XCOM/NIST tabulation. At 30 keV, the absolute dose rate in water at 1.0 cm from the source increases by 7.8% after replacing the DLC-200 photoelectric cross-sections for water with those from the XCOM/NIST tabulation. The differences in the absolute dose rate are analysed when calculated with either the MCNP absorbed dose tally or the collision kerma tally. Significant differences between the collision kerma tally and the absorbed dose tally can occur when using the DLC-200 attenuation coefficients in conjunction with a modern tabulation of mass energy-absorption coefficients.
Objectives To evaluate the technical performance of an ultra-high-resolution CT (UHRCT) system. Methods The physico-technical capabilities of a novel commercial UHRCT system were assessed and compared with those of a current-generation multi-detector (MDCT) system. The super-high-resolution (SHR) mode of the system uses 0.25 mm (at isocentre) detector elements (dels) in the in-plane and longitudinal directions, while the high-resolution (HR) mode bins two dels in the longitudinal direction. The normal-resolution (NR) mode bins dels 2 × 2, resulting in a del-size equivalent to that of the MDCT system. In general, standard procedures and phantoms were used to perform these assessments.Results The UHRCT MTF (10% MTF 4.1 lp/mm) is twice as high as that of the MDCT (10% MTF 1.9 lp/mm), which is comparable to the MTF in the NR mode (10% MTF 1.7 lp/mm). The width of the slice sensitivity profile in the SHR mode (FWHM 0.45 mm) is about 60% of that of the MDCT (FWHM 0.77 mm). Uniformity and CT numbers are within the expected range. Noise in the high-resolution modes has a higher magnitude and higher frequency components compared with MDCT. Low-contrast visibility is lower for the NR, HR and SHR modes compared with MDCT, but about a 14%, for NR, and 23%, for HR and SHR, dose increase gives the same results. Conclusions HR and SHR mode scanning results in double the spatial resolution, with about a 23% increase in dose required to achieve the same low-contrast detectability. Key Points • Resolution on UHRCT is up to twice as high as for the tested MDCT.• With abdominal settings, UHRCT needs higher dose for the same low-contrast detectability as MDCT, but dose is still below achievable levels as defined by current diagnostic reference levels. • The UHRCT system used in normal-resolution mode yields comparable resolution and noise characteristics as the MDCT system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.