2015
DOI: 10.1016/j.compbiomed.2015.04.013
|View full text |Cite
|
Sign up to set email alerts
|

Image-based computational simulation of sub-endothelial LDL accumulation in a human right coronary artery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 48 publications
0
11
0
Order By: Relevance
“…Newtonian and non-Newtonian blood models are also compared in Thanapong Chaicana et al, [12] paper, where there are almost similar values for WSS in both blood models, representing huge similarities in WSS values although having different blood models. Based on the [11,12,8,18,19,21] papers, we can find a mutual agreement of the authors regarding hemodynamic parameters related significantly to the physiological blood flow. Details of the studies can be observed in Table 1 and Table 2.…”
Section: Principle Outcome: Comparison Of Methods Equations and Finmentioning
confidence: 74%
See 3 more Smart Citations
“…Newtonian and non-Newtonian blood models are also compared in Thanapong Chaicana et al, [12] paper, where there are almost similar values for WSS in both blood models, representing huge similarities in WSS values although having different blood models. Based on the [11,12,8,18,19,21] papers, we can find a mutual agreement of the authors regarding hemodynamic parameters related significantly to the physiological blood flow. Details of the studies can be observed in Table 1 and Table 2.…”
Section: Principle Outcome: Comparison Of Methods Equations and Finmentioning
confidence: 74%
“…CFD is a tool that has been used for decades in simulation and fluid flow processes. Many researchers consider this method while underwent experimental and simulation investigation for their research as it is time-consuming and low in cost [8,11,12,[18][19][20]. This CFD method not only limited to the selective field such as the mechanical and fluid field but also brings a great contribution to medical fields.…”
Section: Methodology 21 Data Extraction and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…One condition that is associated with atherosclerosis is the accumulation of LDL-c in the intima-media layer of the artery, together with endothelial dysfunction. The latter, in turn, may result in structural modifications with the accumulation of LDL-c in the arterial intima and, consequently, lead to the formation of atheroma plaques [ 59 , 60 ]. Thereafter, this accumulation of LDL-c may be oxidized and lead to the formation of oxLDL, which results in an increase of adhesion molecules and the secretion of proinflammatory cytokines by endothelial cells with consequent infiltration of monocytes and macrophages within the intima.…”
Section: Common Brazilian Cerrado Campomanesia mentioning
confidence: 99%