Abstract: Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MSn) was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmentation behaviors, re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…Quadrupole mass spectrometer was used with electrospray ionization (ESI) at negative mode for molecules deprotonation to detect the mass of analyzed drugs. Selected ion monitoring (SIM) mode was operated to record only specific m/z values [40,41] (74.1, 223.0 and 443.9 for 6-APA, AMOX, and DIC respectively). Capillary voltage was at 3000 V, and drying gas temperature was at 350°C.…”
Section: Hplc-ms Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Quadrupole mass spectrometer was used with electrospray ionization (ESI) at negative mode for molecules deprotonation to detect the mass of analyzed drugs. Selected ion monitoring (SIM) mode was operated to record only specific m/z values [40,41] (74.1, 223.0 and 443.9 for 6-APA, AMOX, and DIC respectively). Capillary voltage was at 3000 V, and drying gas temperature was at 350°C.…”
Section: Hplc-ms Conditionsmentioning
confidence: 99%
“…From the scan mode, fullmass spectrum was obtained for each component, which relates the m/z with abundance. Figure 3 shows the mass spectra of AMOX, DIC, and 6-APA, showing the ion of interest at m/z � 223.0, 443.9, and 74.1, respectively [40,41]. In SIM mode, the instrument was set to monitor only specific m/z values (74.1, 223.0, and 443.9 for 6-APA, AMOX, and DIC, respectively).…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…radicals display high reactivity, non-selectivity, are simple to produce, and are non-toxic [19]. The use of photocatalytic properties of TiO 2 is restricted owing to its wide band gap, which causes decreasing visible light beneficiation, and therefore TiO 2 cannot adequately gather visible light [20]. Recently, new attempts in this field have been tried to increase the spectral range of the TiO 2 photocatalyst, mainly shifting it to longer wavelengths, as the amount of solar irradiance reaching the Earth is less than 3-5% and UV irradiation is relatively expensive.…”
Section: Introductionmentioning
confidence: 99%