2021
DOI: 10.1155/2021/5570938
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of Ecofriendly HPLC-MS Method for Quantitative Assay of Amoxicillin, Dicloxacillin, and Their Official Impurity in Pure and Dosage Forms

Abstract: Novel, accurate, selective, and rapid high-performance liquid chromatography mass spectrometry method was developed for simultaneous analysis of amoxicillin trihydrate, dicloxacillin sodium, and their official impurity 6-aminopenicillanic acid. The chromatographic separation was carried out by applying the mixture on a C18 column (3.5 µm ps, 100 mm × 4.6 mm id) using acetonitrile:water (65 : 35 by volume) as a mobile phase within only 4 min. The quantitative analysis was executed using single quadrupole mass s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 30 publications
0
4
1
Order By: Relevance
“…The LOQs of the optimized method were low enough to perform the quantitative determination of Amox and Dox in a variety of matrices. Our study's LOD and LOQ values are much lower than those of 0.436 and 1.32 µg/mL [20], 2.14 and 7.15 µg/mL [54], 1.579 and µg/mL, 0.1 and 0.3 mg/mL [41], and 4.785 µg/mL [17] reported for the quantitative determination of Amox, and 1.08 and 3.27 µg/mL [55], and 16 and 54 µg/L [6] stated for Dox in pharmaceutical formulations and wastewater samples using the HPLC method.…”
Section: Linearity Limit Of Detection (Lod) and Limit Of Quantificati...contrasting
confidence: 70%
See 4 more Smart Citations
“…The LOQs of the optimized method were low enough to perform the quantitative determination of Amox and Dox in a variety of matrices. Our study's LOD and LOQ values are much lower than those of 0.436 and 1.32 µg/mL [20], 2.14 and 7.15 µg/mL [54], 1.579 and µg/mL, 0.1 and 0.3 mg/mL [41], and 4.785 µg/mL [17] reported for the quantitative determination of Amox, and 1.08 and 3.27 µg/mL [55], and 16 and 54 µg/L [6] stated for Dox in pharmaceutical formulations and wastewater samples using the HPLC method.…”
Section: Linearity Limit Of Detection (Lod) and Limit Of Quantificati...contrasting
confidence: 70%
“…No antibiotics (Amox and Dox) were detected in the wastewater collected from the sewage system of the two stations from Cluj-Napoca. Lower recovery (97.0 ± 1.6%) for the determination of Amox in spiked wastewater at 10 mg/L was found by Unutkan et al [6], while Almaki et al reported 100.99 ± 1.632% for the assay of Amox in capsules [20].…”
Section: Occurrence Of Amox and Dox In Wastewater Samplesmentioning
confidence: 84%
See 3 more Smart Citations