2015
DOI: 10.1109/tdei.2015.004970
|View full text |Cite
|
Sign up to set email alerts
|

Identification of direct lightning strike faults based on mahalanobis distance and S-transform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 15 publications
0
16
0
Order By: Relevance
“…There are so many direct lightning strike faults, but in practical condition there are only six direct lightning strike faults and those are classified as: The direct lightning strike fault which is damages to the overhead transmission line, to protect the overhead transmission line from direct or indirect lightning strike faults, many scientists invented the different methods. At the starting okabe et al took a photos of the lightning strike process by using the high speed camera capable of direct observing the position of the lightning strike point and insulator string situation to protect the overhead transmission line [1]. But this method is not convenient and also it is practically not accurate method.…”
Section: International Journal Of Engineering Research and Technology (mentioning
confidence: 99%
See 4 more Smart Citations
“…There are so many direct lightning strike faults, but in practical condition there are only six direct lightning strike faults and those are classified as: The direct lightning strike fault which is damages to the overhead transmission line, to protect the overhead transmission line from direct or indirect lightning strike faults, many scientists invented the different methods. At the starting okabe et al took a photos of the lightning strike process by using the high speed camera capable of direct observing the position of the lightning strike point and insulator string situation to protect the overhead transmission line [1]. But this method is not convenient and also it is practically not accurate method.…”
Section: International Journal Of Engineering Research and Technology (mentioning
confidence: 99%
“…The lifetime of the Rogowski coil is 85 years but the lightning strike faults are random, such that numerous Rogowski coils are needed to cover the entire transmission line and hence it is costly [1]. This is the main drawback of this method due to that reason other methods were introduced.…”
Section: Protection Of Overhead Transmission Line By Using Rogowski Cmentioning
confidence: 99%
See 3 more Smart Citations