2005
DOI: 10.1038/sj.leu.2404013
|View full text |Cite
|
Sign up to set email alerts
|

Identification of circulating CD10 positive T cells in angioimmunoblastic T-cell lymphoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
32
0
3

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 43 publications
(36 citation statements)
references
References 24 publications
(31 reference statements)
1
32
0
3
Order By: Relevance
“…2 Among these 28 cases, 12 cases have been previously reported ( Table 1, cases 1-12). 7 In addition to the immunological markers routinely used in T-cell lymphoma diagnosis, the expression of ICOS and PD-1 was evaluated by flow cytometry in 15 lymph nodes and 13 peripheral blood samples. These cases have been cryoconserved in fetal calf serum (FCS; Vysis, Voisins le Bretonneux, France) with 10% dimethyl sulfoxide (DMSO; Sigma, St Louis, MO, USA) in liquid nitrogen until use.…”
Section: Samplesmentioning
confidence: 99%
See 3 more Smart Citations
“…2 Among these 28 cases, 12 cases have been previously reported ( Table 1, cases 1-12). 7 In addition to the immunological markers routinely used in T-cell lymphoma diagnosis, the expression of ICOS and PD-1 was evaluated by flow cytometry in 15 lymph nodes and 13 peripheral blood samples. These cases have been cryoconserved in fetal calf serum (FCS; Vysis, Voisins le Bretonneux, France) with 10% dimethyl sulfoxide (DMSO; Sigma, St Louis, MO, USA) in liquid nitrogen until use.…”
Section: Samplesmentioning
confidence: 99%
“…Methods for immunophenotype analysis by multiparametric flow cytometer have been previously reported. 7 The flow data were acquired on a BD FACSCanto II cytometer, which was daily calibrated with BD Cytometer Setup and Tracking Beads, and were analyzed with BD FACS DIVA software (all from Becton Dickinson). Fresh blood samples were lyzed using BD FACS (lyse/Wash assistant; Becton Dickinson).…”
Section: Flow Cytometrymentioning
confidence: 99%
See 2 more Smart Citations
“…Testing for CD94, CD161, and killer-cell immunoglobulin-like receptors was not helpful in our cases of AITL, in contrast to the diagnostic utility for clones of large granular lymphocytes in the blood (12). Increased CD10 has been described on T cells in 80% of AITL (5,(13)(14)(15), but nonneoplastic CD10-positive FHT may be increased also in lymph node biopsies with reactive hyperplasia and with B-cell lymphoma (6,7).…”
Section: Vbeta Analysis By Flow Cytometry Is a New Techniquementioning
confidence: 49%