2014
DOI: 10.1016/j.ecoleng.2014.06.023
|View full text |Cite
|
Sign up to set email alerts
|

Identification and characterization of dissolved organic matter sources in Kushiro river impacted by a wetland

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 30 publications
0
5
0
2
Order By: Relevance
“…The pH was fixed at 3.0 for fluorescence measurements to minimize potential interference from metals present. Three-dimensional EEM of DOM samples from five reservoirs were analyzed using a Hitachi Fluorescence Spectrophotometer (F-7000) equipped with the Fluorescence Solutions 2.1 software [26,27] for data processing. Fluorescence scans were conducted at excitation wavelengths from 200 to 450 nm using 5 nm increments and emission wavelengths from 280 to 550 nm at 5 nm increments, a bandwidth of 5 nm, and 0.5 s of integration time.…”
Section: Eem Fluorescence Spectroscopymentioning
confidence: 99%
“…The pH was fixed at 3.0 for fluorescence measurements to minimize potential interference from metals present. Three-dimensional EEM of DOM samples from five reservoirs were analyzed using a Hitachi Fluorescence Spectrophotometer (F-7000) equipped with the Fluorescence Solutions 2.1 software [26,27] for data processing. Fluorescence scans were conducted at excitation wavelengths from 200 to 450 nm using 5 nm increments and emission wavelengths from 280 to 550 nm at 5 nm increments, a bandwidth of 5 nm, and 0.5 s of integration time.…”
Section: Eem Fluorescence Spectroscopymentioning
confidence: 99%
“…All analyses were performed in triplicate and analyzed using SPSS 26 and Excel 2016. The 3D fluorescence spectra and parallel factor (PARAFAC) analysis modeling simulations were analyzed using MATLAB (version 2009b) (Shafiquzzaman et al, 2014). Principal coordinates analysis (PCoA) based on the Bray-Curtis distances was used to reveal the beta diversity of the microbial communities.…”
Section: Statistical Analysesmentioning
confidence: 99%
“…Threedimensional fluorescence excitation-emission matrices (EMM) of DOM samples from the Baitapu River were analyzed using a Hitachi Fluorescence Spectrophotometer (F-7000) equipped with the fluorescence solutions 2.1 software (Jamieson et al 2014;Shafiquzzaman et al 2014) for data processing. Fluorescence scans were conducted with excitation wavelengths from 200 to 450 nm at 5 nm increments and emission wavelengths from 280 to 550 nm at 5 nm increments, 5 nm bandwidth and 0.5 s integration time, and Mili-Q filtered water was used as blank.…”
Section: Eem Fluorescence Spectroscopymentioning
confidence: 99%