1983
DOI: 10.1111/j.1525-1594.1983.tb04171.x
|View full text |Cite
|
Sign up to set email alerts
|

In Vitro Assessment of the Hemocompatible Properties of Polymers

Abstract: Based on the available data in the literature and personal results, a system of in vitro tests, consisting of two levels of selection, was proposed for assessment of hemocompatible properties of polymers. The first level consists of rapid methods for preliminary assessment (clotting time, hemolytic activity of the sample, and number of adhesive platelets). The second level involves methods for final selection and consists of measurement of the kinetics of the initial stages of adsorption of albumin, the degree… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

1984
1984
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 0 publications
1
5
0
Order By: Relevance
“…Local topography data obtained with AFM were complemented with X-ray reflectometry thickness measurements, which averaged over large areas. We believe that our observations are consistent with theoretical descriptions of the various simultaneously occurring processes of adsorption, conformational changes, and desorption of protein molecules, 26 which have appeared in the literature, [27][28][29] and we consider our experimental observations in light of those concepts. First we discuss the variation in adsorbed layer morphology with concentration.…”
Section: Discussionsupporting
confidence: 90%
“…Local topography data obtained with AFM were complemented with X-ray reflectometry thickness measurements, which averaged over large areas. We believe that our observations are consistent with theoretical descriptions of the various simultaneously occurring processes of adsorption, conformational changes, and desorption of protein molecules, 26 which have appeared in the literature, [27][28][29] and we consider our experimental observations in light of those concepts. First we discuss the variation in adsorbed layer morphology with concentration.…”
Section: Discussionsupporting
confidence: 90%
“…Whole blood was obtained from at least three donors in tubes containing Li‐heparin as an anticoagulant and the supernatant was collected and used to determine plasma‐free hemoglobin as previously described (DeSilva et al, ; Malinauskas, ; Sevastianov et al, ). EVs were added, and 10 mg ml −1 poly‐ l ‐lysine and polyethylene glycol (40% stock solution) were used as positive and negative controls respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Platelet adhesion was determined according to the following procedure [17,32]: brie y, whole blood of healthy adult donors was drawn by venipuncture into siliconized glass vials. 10 ml blood was anticoagulated 9 : 1 with sodium citrate.…”
Section: Investigation Of Hemocompatibility Of Phasmentioning
confidence: 99%
“…Low density polyethylene (LDPE) for medical use served as a control (N contr tot , N contr i ) sample. RIPA did not depend on biological variability of blood properties of different donors [32], which allowed using several donors with results being averaged afterwards. Student's t-test was applied to check the difference of average values whenever necessary.…”
Section: Investigation Of Hemocompatibility Of Phasmentioning
confidence: 99%