2019
DOI: 10.1088/1361-6579/ab3c0e
|View full text |Cite
|
Sign up to set email alerts
|

Ex vivo quantification of lanthanum and gadolinium in post-mortem human tibiae with estimated barium and iodine concentrations using K x-ray fluorescence

Abstract: Objectives: Lanthanum (La) and gadolinium (Gd) are known to deposit in bone of exposed populations, namely those who are orally administered lanthanum carbonate (LaC, La 2 (CO 3 ) 3 ) or are injected with Gd-based contrast agents, respectively. In this work, bone La and Gd concentrations from the environment and diet were measured using x-ray fluorescence in ten post-mortem human tibiae. As a secondary objective, bone barium (Ba) and iodine concentrations were estimated. Approach: Two calibration lines were pr… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(15 citation statements)
references
References 48 publications
0
5
0
Order By: Relevance
“…This review would not be complete without mention of XRF spectrometry for the analysis of bone . Nguyen et al 105 focussed on the quantification of La and Gd by KXRF spectrometry, with Ba and I inferred from sensitivity factors derived from the La calibration line and Monte Carlo simulations. Tibiae from human cadavers were obtained from individuals with no known exposure to either La ( e.g.…”
Section: Progress With Analytical Techniquesmentioning
confidence: 99%
“…This review would not be complete without mention of XRF spectrometry for the analysis of bone . Nguyen et al 105 focussed on the quantification of La and Gd by KXRF spectrometry, with Ba and I inferred from sensitivity factors derived from the La calibration line and Monte Carlo simulations. Tibiae from human cadavers were obtained from individuals with no known exposure to either La ( e.g.…”
Section: Progress With Analytical Techniquesmentioning
confidence: 99%
“…All experimental coherently normalized data points are shown as an average of three independent measurements. Peak fitting was performed in OriginPro 2019 (OriginLab Corp., Northampton, MA, USA) with the fitting function described in our previous work (Nguyen et al 2019).…”
Section: Experimental Setup and Measurementmentioning
confidence: 99%
“…A sample XRF spectrum of the bare hydroxyapatite phantom is shown in figure 5 where the inset graph illustrates the four term Gaussian function used to fit the La Kα 1,2 x-ray signals at 33.4 keV and 33.0 keV, in addition to Ba Kα x-ray peaks that originated from the powders used to create the hydroxyapatite phantom and the fourth Gaussian peak was used to fit a 33.2 keV gamma emission from the 241 Am source (Nguyen et al 2019).…”
Section: Coherent Normalization As a Function Of Overlying Tissue Thi...mentioning
confidence: 99%
See 2 more Smart Citations